Valor preditivo positivo das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS®)

  • Prado G
  • Guerra M
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

OBJETIVO: O objetivo deste trabalho foi avaliar o BI-RADS® como fator preditivo de suspeição de malignidade em lesões mamárias não palpáveis nas categorias 3, 4 e 5, correlacionando as mamografias com os resultados histopatológicos através do cálculo do valor preditivo positivo do exame mamográfico. MATERIAIS E MÉTODOS: Trezentas e setenta e uma pacientes encaminhadas a um serviço de referência em tratamento de câncer em Teresina, PI, para realização de exames histopatológicos em mama no período de julho de 2005 a março de 2008, por terem mamografia de categorias 3, 4 ou 5, tiveram seus exames revisados. Das 371 pacientes, 265 foram submetidas a biópsia por agulha grossa e 106, a marcação pré-cirúrgica. RESULTADOS: Em relação às mamografias, 11,32% foram classificadas como categoria 3, 76,28% como categoria 4 e 12,4% como categoria 5. Os resultados histológicos demonstraram 24% de exames positivos para malignidade. Os valores preditivos positivos das categorias 3, 4 e 5 foram, respectivamente, de 7,14%, 16,96% e 82,61%. Foram calculados os valores preditivos positivos, separadamente, para as biópsias percutâneas (7,14%, 15,76%, 76,47%) e para as marcações pré-cirúrgicas (7,14%, 20%, 100%). CONCLUSÃO: Achados malignos foram subestimados pelo laudo radiológico e houve superestimação de achados benignos, o que resultou na realização desnecessária de alguns procedimentos invasivos.OBJECTIVE: The present study was aimed at evaluating BI-RADS® 3, 4 and 5 categories as positive predictive value for malignancy of non-palpable breast lesions, correlating mammographic and histopathological findings. MATERIALS AND METHODS: In the period from July/2005 to March/2008, 371 patients with mammograms classified as BI-RADS categories 3, 4 and 5 were referred to a center of reference in cancer treatment in Terezina, PI, Brazil, for histopathological investigation and had their mammograms reviewed. Among these 371 patients, 265 were submitted to core-biopsy and 106 to preoperative needle localization. RESULTS: Mammograms were classified as follows: 11.32% category 3, 76.28% category 4 and 12.4% category 5. The histopathological studies demonstrated 24% of results positive for malignancy. Positive predictive values for categories 3, 4 and 5 were, respectively, 7.14%, 16.96% and 82.61%. Positive predictive values were separately calculated for core-biopsies (7.14%, 15.76%, and 76.47%) and pre-surgical needle localization (7.14%, 20%, 100%). CONCLUSION: Malignant findings were underestimated, and benign findings were overestimated by mammographic reports, thus resulting in some unnecessary invasive procedures.

Cite

CITATION STYLE

APA

Prado, G. L. M., & Guerra, M. T. P. M. (2010). Valor preditivo positivo das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS®). Radiologia Brasileira, 43(3), 171–174. https://doi.org/10.1590/s0100-39842010000300008

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free