Velocity-domain motion quality measures for surgical performance evaluation and feedback

1Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Endovascular navigation proficiency requires a significant amount of manual dexterity from surgeons. Objective performance measures derived from endovascular tool tip kinematics have been shown to correlate with expertise; however, such metrics have not yet been used during training as a basis for real-time performance feedback. This paper evaluates a set of velocity-based performance measures derived from guidewire motion to determine their suitability for online performance evaluation and feedback. We evaluated the endovascular navigation skill of 75 participants using three metrics (spectral arc length, average velocity, and idle time) as they steered tools to anatomical targets using a virtual reality simulator. First, we examined the effect of navigation task and experience level on performance and found that novice performance was significantly different from intermediate and expert performance. Then we computed correlations between measures calculated online and spectral arc length, our “gold standard” metric, calculated offline (at the end of the trial, using data from the entire trial). Our results suggest that average velocity and idle time calculated online are strongly and consistently correlated with spectral arc length computed offline, which was not the case when comparing spectral arc length computed online and offline. Average velocity and idle time, both time-domain based performance measures, are therefore more suitable measures than spectral arc length, a frequency-domain based metric, to use as the basis of online performance feedback. Future work is needed to determine how to best provide real-time performance feedback to endovascular surgery trainees based on these metrics.

References Powered by Scopus

Transcatheter versus surgical aortic-valve replacement in high-risk patients

5482Citations
N/AReaders
Get full text

Unruptured intracranial aneurysms: Natural history, clinical outcome, and risks of surgical and endovascular treatment

3229Citations
N/AReaders
Get full text

A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms

1800Citations
N/AReaders
Get full text

Cited by Powered by Scopus

M1 transcranial direct current stimulation augments laparoscopic surgical skill acquisition

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Murali, B., Belvroy, V. M., Pandey, S., Bismuth, J., Byrne, M. D., & O’Malley, M. K. (2021). Velocity-domain motion quality measures for surgical performance evaluation and feedback. Journal of Medical Devices, Transactions of the ASME, 15(1). https://doi.org/10.1115/1.4049310

Readers over time

‘21‘22‘23‘2402468

Readers' Seniority

Tooltip

Researcher 3

60%

Lecturer / Post doc 1

20%

PhD / Post grad / Masters / Doc 1

20%

Readers' Discipline

Tooltip

Computer Science 2

29%

Medicine and Dentistry 2

29%

Psychology 2

29%

Decision Sciences 1

14%

Save time finding and organizing research with Mendeley

Sign up for free
0