The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments

43Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

Abstract

Most macromolecular crystallography (MX) diffraction experiments at synchrotrons use a single-axis goniometer. This markedly contrasts with small-molecule crystallography, in which the majority of the diffraction data are collected using multi-axis goniometers. A novel miniaturized κ-goniometer head, the MK3, has been developed to allow macromolecular crystals to be aligned. It is available on the majority of the structural biology beamlines at the ESRF, as well as elsewhere. In addition, the Strategy for the Alignment of Crystals (STAC) software package has been developed to facilitate the use of the MK3 and other similar devices. Use of the MK3 and STAC is streamlined by their incorporation into online analysis tools such as EDNA. The current use of STAC and MK3 on the MX beamlines at the ESRF is discussed. It is shown that the alignment of macromolecular crystals can result in improved diffraction data quality compared with data obtained from randomly aligned crystals.

References Powered by Scopus

A short history of SHELX

84493Citations
N/AReaders
Get full text

XDS

13564Citations
N/AReaders
Get full text

Scaling and assessment of data quality

4099Citations
N/AReaders
Get full text

Cited by Powered by Scopus

MASSIF-1: A beamline dedicated to the fully automatic characterization and data collection from crystals of biological macromolecules

120Citations
N/AReaders
Get full text

MeshAndCollect: An automated multi-crystal data-collection workflow for synchrotron macromolecular crystallography beamlines

97Citations
N/AReaders
Get full text

ID30B – a versatile beamline for macromolecular crystallography experiments at the ESRF

74Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Brockhauser, S., Ravelli, R. B. G., & McCarthy, A. A. (2013). The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments. Acta Crystallographica Section D: Biological Crystallography, 69(7), 1241–1251. https://doi.org/10.1107/S0907444913003880

Readers over time

‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 21

48%

Researcher 16

36%

Professor / Associate Prof. 5

11%

Lecturer / Post doc 2

5%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 18

43%

Chemistry 11

26%

Biochemistry, Genetics and Molecular Bi... 9

21%

Physics and Astronomy 4

10%

Save time finding and organizing research with Mendeley

Sign up for free
0