ISO-CADICA: Isotopic - Continuous, automated dissolved inorganic carbon analyser

28Citations
Citations of this article
68Readers
Mendeley users who have this article in their library.
Get full text

Abstract

RATIONALE Quantifying the processes that control dissolved inorganic carbon (DIC) dynamics in aquatic systems is essential for progress in ecosystem carbon budgeting. The development of a methodology that allows high-resolution temporal data collection over prolonged periods is essential and is described in this study. METHODS A novel sampling instrument that sequentially acidifies aliquots of water and utilises gas-permeable ePTFE tubing to measure the dissolved inorganic carbon (DIC) concentration and δ13C DIC values at sub-hourly intervals by Cavity Ring-down spectrometry (CRDS) is described. RESULTS The minimum sensitivity of the isotopic, continuous, automated dissolved inorganic carbon analyser (ISO-CADICA) system is 0.01 mM with an accuracy of 0.008 mM. The analytical uncertainty in δ13CDIC values is proportional to the concentration of DIC in the sample. Where the DIC concentration is greater than 0.3 mM the analytical uncertainty is ±0.1 ° and below 0.2 mM stability is < ± 0.3 °. The isotopic effects of air temperature, water temperature and CO2 concentrations were found to either be negligible or correctable. Field trials measuring diel variation in δ13C DIC values of coral reef associated sea water revealed significant, short-term temporal changes and illustrated the necessity of this technique. CONCLUSIONS Currently, collecting and analysing large numbers of samples for δ13CDIC measurements is not trivial, but essential for accurate carbon models, particularly on small scales. The ISO-CADICA enables on-site, high-resolution determination of DIC concentration and δ13CDIC values with no need for sample storage and laboratory analysis. The initial tests indicate that this system can offer accuracy approaching that of traditional IRMS analysis. Copyright © 2012 John Wiley & Sons, Ltd.

Cite

CITATION STYLE

APA

Bass, A. M., Bird, M. I., Munksgaard, N. C., & Wurster, C. M. (2012). ISO-CADICA: Isotopic - Continuous, automated dissolved inorganic carbon analyser. Rapid Communications in Mass Spectrometry, 26(6), 639–644. https://doi.org/10.1002/rcm.6143

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free