XRF identification of sharp-force trauma in fresh and dry human bone under varied experimental heat conditions

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Heat-induced fractures can be hard to distinguish from sharp force traumas. This challenge can negatively impact medico-legal analysis. The present study aimed to experimentally assess if X-ray fluorescence (XRF) can be used to detect chemical traces transferred from the blade of a sharp instrument onto both fresh and dry human bones. This was performed by inducing sharp force traumas with five different instruments on 20 fresh and 20 dry human clavicles. All bone samples were probed before and after experimental burning (at 500 °C, 700 °C, 900 °C and 1100 °C). Our results show that XRF is potentially useful for detecting iron traces in fresh human bone, both unburned and burned. However, we were not able to clearly detect iron traces from the blades in bones that have been previously inhumed, since exogenous iron acquired during diagenesis masks the iron traces originating from the blade.

Cite

CITATION STYLE

APA

Rosa, J., Batista de Carvalho, L. A. E., Marques, M. P. M., Ferreira, M. T., Gonçalves, D., & Gil, F. P. S. C. (2024). XRF identification of sharp-force trauma in fresh and dry human bone under varied experimental heat conditions. Science and Justice, 64(3), 305–313. https://doi.org/10.1016/j.scijus.2024.04.005