Diagnostic role of contrast-enhanced ultrasonography versus conventional B-mode ultrasonography in cirrhotic patients with early hepatocellular carcinoma: a retrospective study

5Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Background: Early diagnosis of hepatocellular carcinoma (HCC) is very important for the prognosis of patients. However, there are very few studies that compared the diagnostic accuracy of contrast-enhanced ultrasonography (CEUS) and B-mode ultrasonography for early HCC in cirrhotic patients. Methods: This retrospective study included cirrhotic patients, who were suspected of early HCC between January 2020 and June 2021. The diagnosis of patients was based on the pathology results of surgery or biopsy. Demographic and clinical characteristics of included patients were recorded. The diagnoses of suspected lesions using both types of ultrasonography were recorded, and the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of early HCC in cirrhotic patients were calculated. Results: Eventually, 137 patients with solitary lesions in the liver were included in this study, including 89 patients diagnosed with HCC and 48 patients diagnosed with non-HCC. The median diameter of suspected lesions was 26 mm, and the median level of alpha fetoprotein (AFP) was 37.2 ng/mL. When comparing the demographic and clinical characteristics of cirrhotic patients with HCC and non-HCC, it was found that patients with HCC had significantly higher levels of AFP than those with non-HCC (P=0.03). The sensitivity, specificity, PPV, NPV, and accuracy of CEUS in early HCC were 73%, 93.8%, 95.6%, 65.2% and 80.3%, respectively. In CEUS, all of these parameters were much higher than those in B-mode ultrasonography, i.e., 64%, 75%, 82.6%, 52.9%, and 67.9%. It was also found that the diagnostic accuracy of CEUS was much higher than that of B-mode ultrasonography especially regarding lesions <20 mm. To further improve the sensitivity of CEUS in early HCC, AFP was combined with CEUS for the diagnosis of early HCC. As a result, the sensitivity, specificity, PPV, NPV, and accuracy of CEUS combined with AFP level were 83.1%, 87.5%, 92.5%, 73.7%, and 84.7%, respectively. Conclusions: Our study confirmed that CEUS’ diagnostic accuracy for early HCC in cirrhotic patients was significantly higher than that of B-mode ultrasonography. However, the sensitivity of CEUS needs to be improved further, and the combination of CEUS and AFP level may be a potential solution.

Cite

CITATION STYLE

APA

Jiang, Y., Zhang, M., Zhu, Y., & Zhu, D. (2021). Diagnostic role of contrast-enhanced ultrasonography versus conventional B-mode ultrasonography in cirrhotic patients with early hepatocellular carcinoma: a retrospective study. Journal of Gastrointestinal Oncology, 12(5), 2403–2411. https://doi.org/10.21037/jgo-21-611

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free