Hemodynamic follow-up after valve-in-valve TAVR for failed aortic bioprosthesis

0Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: “valve-in-valve” TAVR (VIV-TAVR) is established and provides good initial clinical and hemodynamic outcomes. Lacking long-term durability data baffle the expand to lower risk patients. For those purposes, the present study adds a hemodynamic 3-years follow-up. Methods: A total of 77 patients underwent VIV-TAVR for failing aortic bioprosthesis during a 7-years period. Predominant mode of failure was stenosis in 87.0%. Patients had a mean age of 79.4 ± 5.8 years and a logistic EuroSCORE of 30.8 ± 15.7%. The Society of Thoracic Surgeons-PROM averaged 5.79 ± 2.63%. Clinical results and hemodynamic outcomes are reported for 30-days, 1-, 2-, and 3-years. Completeness of follow-up was 100% with 44 patients at risk after 3-years. Follow-up ranged up to 7.1 years. Results: Majority of the surgical valves were stented (94.8%) with a mean labeled size of 23.1 ± 2.3 mm and true-ID of 20.4 ± 2.6 mm. A true-ID ≤21 mm had 58.4% of the patients. Self-expanding valves were implanted in 68.8% (mean labeled size 24.1 ± 1.8 mm) and balloon-expanded in 31.2% (mean size 24.1 ± 1.8 mm). No patient died intraoperatively. Hospital mortality was 1.3% and three-years survival 57.1%. All patients experienced an initial significant dPmean-reduction to 16.8 ± 7.1 mmHg. After 3-years mean dPmean raised to 26.0 ± 12.2 mmHg. This observation was independent from true-ID or type of transcatheter aortic valve replacement (TAVR)-prosthesis. Patients with a true-ID ≤21 mm had a higher initial (18.3 ± 5.3 vs. 14.9 ± 7.1 mmHg; p =.005) and dPmean after 1-year (29.2 ± 8.2 vs. 13.0 ± 6.7 mmHg; p =.004). There were no significant differences in survival. Conclusions: VIV-TAVR is safe and effective in the early period. In surgical valves with a true-ID ≤21 mm inferior hemodynamic and survival outcomes must be expected. Nonetheless, also patients with larger true-IDs showed steadily increasing transvalvular gradients. This raises concern about durability.

Cite

CITATION STYLE

APA

Wilbring, M., Kappert, U., Haussig, S., Winata, J., Matschke, K., Mangner, N., … Alexiou, K. (2022). Hemodynamic follow-up after valve-in-valve TAVR for failed aortic bioprosthesis. Journal of Cardiac Surgery, 37(12), 4654–4661. https://doi.org/10.1111/jocs.17048

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free