Abstract

Background/Aims: This study was to determine the test–retest repeatability in quantifying macular capillary perfusion density (CPD, expressed as fractal dimension) using optical coherence tomography angiography (OCTA) in a multi-center setting. Methods: OCTA data were obtained in self-reported healthy subjects from Bascom Palmer Eye Institute at the University of Miami (UM, N = 18) and the University of Pennsylvania (UPenn, N = 22). The right eye of each subject was imaged twice at the first visit and then again at an interval of one week to assess intra-visit and inter-visit repeatability. The macular area of the OCTA-derived capillary perfusion density (OCTA-CPD) was analyzed by custom-made image processing and fractal analysis software. Fractal analysis was performed on the skeletonized microvascular network to yield OCTA-CPD by box-counting to the fractal dimension (Dbox) in the superficial vascular plexus (SVP). Repeatability was assessed by three measures: within-subject standard deviation (Sw), coefficient of variation (CoV) of repeated measures, and intraclass correlation coefficient (ICC). Results: OCTA-CPD from both sites (UM and UPENN) showed good to excellent intra-visit repeatability, as demonstrated by the Sw ≤0.004, CoVs ≤0.23%, and ICCs ≥0.61. Similarly, both sites had good to excellent inter-visit repeatability, as shown by the Sw ≤0.005, CoVs ≤0.28%, and ICCs ≥0.61. The Bland-Altman plots of the intra-visit and inter-visit measurements showed excellent agreements between the paired measurements with minimal biases. Conclusion: Our data showed that comparable high repeatability of OCTA-CPD can be achieved in both research sites using the same device, scan protocol, and image analysis.

Cite

CITATION STYLE

APA

Jiang, H., Simms, A. G., Sadaghiani, S., Jiang, Y. Y., Morgan, J. I. W., Aguirre, G. K., … Wang, J. (2022). Multi-Center Repeatability of Macular Capillary Perfusion Density Using Optical Coherence Tomography Angiography. Clinical Ophthalmology, 16, 3069–3078. https://doi.org/10.2147/OPTH.S383770

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free