The present work describes the development of a new high performance liquid chromatographic (HPLC) method for the determination of Cefixime trihydrate under different stress conditons as specified by ICH. For the analysis, a Phenomenex (250 x 4.6 mm, 5 μm particle size) ODS column and a SPD 20 A UV detector at 289 nm was used. The selected mobile phase was 10 mM disodium hydrogen phosphate (with 0.5% TEA, pH adjusted to 6.3 with OPA) and methanol in the ratio of 75:25 (v/v) in isocratic mode at a flow rate of 1 mL.min-1.The linear regression analysis data for the calibration plots showed good linear relationship with r2= 0.9997 in the concentration range of 5-100 μg.mL-1. The stress degradation was performed using acid, alkali, water, hydrogen peroxide and uv light.
CITATION STYLE
Mathew, C., Swathi, B., Ajitha, M., & Babu, P. S. (2016). Development and validation of a new and economical stability indicating RP-HPLC method for cefixime trihydrate. Brazilian Journal of Pharmaceutical Sciences, 52(1), 87–94. https://doi.org/10.1590/S1984-82502016000100010