The metrological traceability, performance and precision of european radon calibration facilities

10Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k = 2). For lower exposure levels, the variation increased to about 6%.

References Powered by Scopus

The evaluation of key comparison data

531Citations
N/AReaders
Get full text

Determination of a reference value and its uncertainty through a power-moderated mean

104Citations
N/AReaders
Get full text

Weighted means statistics in interlaboratory studies

70Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Investigation of the Performance of Various Low-Cost Radon Monitors under Variable Environmental Conditions

7Citations
N/AReaders
Get full text

Radon Exposure Concentrations in Finnish Workplaces

7Citations
N/AReaders
Get full text

Metrology infrastructure for radon metrology at the environmental level

4Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Beck, T. R., Antohe, A., Cardellini, F., Cucoş, A., Fialova, E., Grossi, C., … Wołoszczuk, K. (2021). The metrological traceability, performance and precision of european radon calibration facilities. International Journal of Environmental Research and Public Health, 18(22). https://doi.org/10.3390/ijerph182212150

Readers' Seniority

Tooltip

Researcher 7

88%

PhD / Post grad / Masters / Doc 1

13%

Readers' Discipline

Tooltip

Environmental Science 3

43%

Chemistry 2

29%

Sports and Recreations 1

14%

Earth and Planetary Sciences 1

14%

Save time finding and organizing research with Mendeley

Sign up for free