Inter- and intraobserver reliability of non-weight-bearing foot radiographs compared with CT in Lisfranc injuries

12Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Injury of the tarsometatarsal (TMT) joint complex, known as Lisfranc injury, covers a wide range of injuries from subtle ligamentous injuries to severely displaced crush injuries. Although it is known that these injuries are commonly missed, the literature on the accuracy of the diagnostics is limited. The diagnostic accuracy of non-weight-bearing radiography (inter- or intraobserver reliability), however, has not previously been assessed among patients with Lisfranc injury. Methods: One hundred sets of foot radiographs acquired due to acute foot injury were collected and anonymised. The diagnosis of these patients was confirmed with a CT scan. In one-third of the radiographs, there was no Lisfranc injury; in one-third, a nondisplaced (' 2 mm) injury; and in one-third, a displaced injury. The radiographs were assessed independently by three senior orthopaedic surgeons and three orthopaedic surgery residents. Results: Fleiss kappa (κ) coefficient for interobserver reliability resulted in moderate correlation κ = 0.50 (95% CI: 0.45– 0.55) (first evaluation) and κ = 0.58 (95% CI: 0.52–0.63) (second evaluation). After three months, the evaluation was repeated and the Cohen’s kappa (κ) coefficient for intraobserver reliability showed substantial correlation κ = 0.71 (from 0.64 to 0.85). The mean (range) sensitivity was 76.1% (60.6–92.4) and specificity was 85.3% (52.9–100). The sensitivity of subtle injuries was lower than severe injuries (65.4% vs 87.1% p = 0.003). Conclusions: Diagnosis of Lisfranc injury based on non-weight-bearing radiographs has moderate agreement between observers and substantial agreement between the same observer in different moments. A substantial number (24%) of injuries are missed if only non-weight-bearing radiographs are used. Nondisplaced injuries were more commonly missed than displaced injuries, and therefore, special caution should be used when the clinical signs are subtle. Level of evidence: III.

References Powered by Scopus

The measurement of observer agreement for categorical data

60806Citations
N/AReaders
Get full text

Statistics Notes: Diagnostic tests 1: Sensitivity and specificity

1680Citations
N/AReaders
Get full text

Statistics Notes: Diagnostic tests 2: Predictive values

1414Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Weight-bearing cone-beam CT: the need for standardised acquisition protocols and measurements to fulfill high expectations—a review of the literature

13Citations
N/AReaders
Get full text

Outcomes after nonoperatively treated non-displaced Lisfranc injury: a retrospective case series of 55 patients

13Citations
N/AReaders
Get full text

Outcome after nonoperative treatment of stable Lisfranc injuries. A prospective cohort study

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ponkilainen, V. T., Partio, N., Salonen, E. E., Riuttanen, A., Luoma, E. L., Kask, G., … Haapasalo, H. H. (2020). Inter- and intraobserver reliability of non-weight-bearing foot radiographs compared with CT in Lisfranc injuries. Archives of Orthopaedic and Trauma Surgery, 140(10), 1423–1429. https://doi.org/10.1007/s00402-020-03391-w

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

82%

Researcher 2

12%

Lecturer / Post doc 1

6%

Readers' Discipline

Tooltip

Medicine and Dentistry 11

85%

Sports and Recreations 1

8%

Nursing and Health Professions 1

8%

Save time finding and organizing research with Mendeley

Sign up for free