Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement

3Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

The ability to generate force in the lower body can be considered a performance factor in sports. This study aims to analyze the test–retest and between-device reliability related to the location on the body of the inertial measurement unit Vmaxpro for the estimation of vertical jump. Eleven highly trained female athletes performed 220 countermovement jumps (CMJ). Data were simultaneously captured by two Vmaxpro units located between L4 and L5 vertebrae (hip method) and on top of the tibial malleolus (ankle method). Intrasession reliability was higher for ankle (ICC = 0.96; CCC = 0.93; SEM = 1.0 cm; CV = 4.64%) than hip (ICC = 0.91; CCC = 0.92; SEM = 3.4 cm; CV = 5.13%). In addition, sensitivity was higher for ankle (SWC = 0.28) than for the hip method (SWC = 0.40). The noise of the measurement (SEM) was higher than the worthwhile change (SWC), indicating lack of ability to detect meaningful changes. The agreement between methods was moderate (rs = 0.84; ICC = 0.77; CCC = 0.25; SEM = 1.47 cm). Significant differences were detected between methods (−8.5 cm, p < 0.05, ES = 2.2). In conclusion, the location of the device affects the measurement by underestimating CMJ on ankle. Despite the acceptable consistency of the instrument, the results of the reliability analysis reveal a significant magnitude of both random and systematic error. As such, the Vmaxpro should not be considered a reliable instrument for measuring CMJ.

References Powered by Scopus

Intraclass correlations: Uses in assessing rater reliability

19136Citations
N/AReaders
Get full text

Progressive statistics for studies in sports medicine and exercise science

7272Citations
N/AReaders
Get full text

Measures of reliability in sports medicine and science

3775Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Validity and Reliability of a Commercially Available Inertial Sensor for Measuring Barbell Mechanics during Weightlifting

1Citations
N/AReaders
Get full text

Is the EnodePro<sup>®</sup> a Valid Tool to Determine the Bar Velocity in the Bench Press and Barbell Back Squat? A Comparative Analysis

0Citations
N/AReaders
Get full text

Reliability and Sensitivity of Enode/Vmaxpro Sensor for Muscle Power Assessment

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Villalon-Gasch, L., Jimenez-Olmedo, J. M., Olaya-Cuartero, J., & Pueo, B. (2023). Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement. Sensors, 23(4). https://doi.org/10.3390/s23042068

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

88%

Lecturer / Post doc 1

13%

Readers' Discipline

Tooltip

Sports and Recreations 4

57%

Medicine and Dentistry 2

29%

Social Sciences 1

14%

Save time finding and organizing research with Mendeley

Sign up for free