Abstract

Objective. To report on a micro computed tomography (micro-CT) system capable of x-ray phase contrast imaging and of increasing spatial resolution at constant magnification. Approach. The micro-CT system implements the edge illumination (EI) method, which relies on two absorbing masks with periodically spaced transmitting apertures in the beam path; these split the beam into an array of beamlets and provide sensitivity to the beamlets’ directionality, i.e. refraction. In EI, spatial resolution depends on the width of the beamlets rather than on the source/detector point spread function (PSF), meaning that resolution can be increased by decreasing the mask apertures, without changing the source/detector PSF or the magnification. Main results. We have designed a dedicated mask featuring multiple bands with differently sized apertures and used this to demonstrate that resolution is a tuneable parameter in our system, by showing that increasingly small apertures deliver increasingly detailed images. Phase contrast images of a bar pattern-based resolution phantom and a biological sample (a mouse embryo) were obtained at multiple resolutions. Significance. The new micro-CT system could find application in areas where phase contrast is already known to provide superior image quality, while the added tuneable resolution functionality could enable more sophisticated analyses in these applications, e.g. by scanning samples at multiple scales.

References Powered by Scopus

Fiji: An open-source platform for biological-image analysis

43321Citations
N/AReaders
Get full text

Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object

1611Citations
N/AReaders
Get full text

X-ray phase-contrast imaging: From pre-clinical applications towards clinics

594Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Nyquist-compliant cycloidal computed tomography

3Citations
N/AReaders
Get full text

X-ray micro-computed tomography with amplitude modulated beams (beam tracking, edge illumination): opportunities, challenges, and outlook

1Citations
N/AReaders
Get full text

Multi-resolution gratings for edge illumination x-ray phase contrast imaging: a simulation study

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Zekavat, A. R., Lioliou, G., Roche i Morgó, O., Maughan Jones, C., Galea, G., Maniou, E., … Hagen, C. (2024). Phase contrast micro-CT with adjustable in-slice spatial resolution at constant magnification. Physics in Medicine and Biology, 69(10). https://doi.org/10.1088/1361-6560/ad4000

Readers over time

‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

50%

Researcher 2

33%

Lecturer / Post doc 1

17%

Readers' Discipline

Tooltip

Physics and Astronomy 2

33%

Computer Science 2

33%

Chemistry 1

17%

Materials Science 1

17%

Save time finding and organizing research with Mendeley

Sign up for free
0