High-performance thin-layer chromatography for the determination of nimesulide in human plasma, and its use in pharmacokinetic studies

30Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A rapid and sensitive high-performance thin-layer chromatographic assay has been developed for the measurement of nimesulide in human plasma. Its use for pharmacokinetic studies has been evaluated. The method includes a single-stage extraction procedure without the use of an internal standard. Analysis was performed on plasma containing known amounts of the drug, on drug-free plasma, and on plasma containing an unknown quantity of the drug. Known amounts of extract and nimesulide (100 and 200 ng, as external standard) were spotted on precoated silica-gel 60F254 plates by means of a Camag Linomat IV autosampler. Quantification was achieved using a Camag TLC scanner 3. The recovery of the method was 97.10 ± 2.22%. The method was applied for the determination of plasma levels and pharmacokinetic parameters of nimesulide after oral administration of two formulations (100 mg) in healthy volunteers. The method is a sensitive, economical, rapid and specific assay for nimesulide in human plasma, and is suitable for pharmacokinetic studies after therapeutic doses.

Cite

CITATION STYLE

APA

Pandya, K. K., Satia, M. C., Modi, I. A., Modi, R. I., Chakravarthy, B. K., & Gandhi, T. P. (1997). High-performance thin-layer chromatography for the determination of nimesulide in human plasma, and its use in pharmacokinetic studies. Journal of Pharmacy and Pharmacology, 49(8), 773–776. https://doi.org/10.1111/j.2042-7158.1997.tb06110.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free