Successful introduction of robotic-assisted percutaneous coronary intervention system into Japanese clinical practice: a first-year survey at single center

17Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In Japan, a robotic-assisted PCI (R-PCI) system, the CorPath GRX System (Corindus Inc.), has been approved for clinical use in 2018, which is the first introduction of R-PCI into Japan. In this study, the clinical performance of the R-PCI system in the initial year at Kurume University Hospital was evaluated comparing with conventional manual PCI (M-PCI). A total of 30 R-PCI and 77 M-PCI procedures performed between April 2019 and March 2020, were retrospectively included. The primary outcome was the rate of clinical success defined as < 30% residual stenosis without in-hospital major adverse cardiovascular events (MACE). The secondary outcomes were fluoroscopy time, dose area product (DAP), amount of radiation exposure to operators and assistants, procedural time, and contrast volume. Propensity-matching technique was used to match each R-PCI lesion to the nearest M-PCI lesion without replacement. After propensity score matching, 30 R-PCI procedures in 28 patients and 37 M-PCI procedures in 35 patients were analyzed. Clinical success rate with R-PCI was favorable and comparable to M-PCI (93.3 vs. 94.6%, p = 0.97), without any in-hospital MACE. The operator radiation exposure was significantly lower in R-PCI (0 vs. 24.5 µSV, p < 0.0001). Radiation exposure to the patients was tended to be reduced by R-PCI (DAP: 77.6 vs. 100.2 Gycm2, p = 0.07). There were no statistically significant differences in radiation exposure to the assistant, fluoroscopy time, procedural time and contrast volume between the two groups (radiation exposure to the assistant: 10.5 vs. 10.0 µSV, p = 0.64, fluoroscopy time: 27.5 vs. 30.1 min, p = 0.55, procedural time: 72.4 vs. 61.6 min, p = 0.23, and contrast volume: 93.2 vs. 102.0 ml, p = 0.36). R-PCI in selected patients demonstrated favorable clinical outcomes with dramatical reduction of radiation exposure to operators.

Cite

CITATION STYLE

APA

Kagiyama, K., Mitsutake, Y., Ueno, T., Sakai, S., Nakamura, T., Yamaji, K., … Fukumoto, Y. (2021). Successful introduction of robotic-assisted percutaneous coronary intervention system into Japanese clinical practice: a first-year survey at single center. Heart and Vessels, 36(7), 955–964. https://doi.org/10.1007/s00380-021-01782-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free