Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices

23Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusionweighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm3, respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm3) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

References Powered by Scopus

Protected carotid-artery stenting versus endarterectomy in high-risk patients

2686Citations
N/AReaders
Get full text

Silent brain infarcts and the risk of dementia and cognitive decline

2040Citations
N/AReaders
Get full text

Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging

951Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: A meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion

82Citations
N/AReaders
Get full text

Flow reversal versus filter protection a pilot carotid artery stenting randomized trial

40Citations
N/AReaders
Get full text

Silent brain infarcts on diffusion-weighted imaging after carotid revascularisation: A surrogate outcome measure for procedural stroke? A systematic review and meta-analysis

36Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Taha, M. M., Maeda, M., Sakaida, H., Kawaguchi, K., Toma, N., Yamamoto, A., … Taki, W. (2009). Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices. Neurologia Medico-Chirurgica, 49(9), 386–393. https://doi.org/10.2176/nmc.49.386

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 11

52%

Researcher 8

38%

Professor / Associate Prof. 2

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 18

78%

Neuroscience 2

9%

Engineering 2

9%

Computer Science 1

4%

Save time finding and organizing research with Mendeley

Sign up for free