Abstract

Optimal conditions for the detection of heat-injured cells of Listeria monocytogenes in modified Pennsylvania State University (mPSU) broth were determined using a response surface design generated by a computer program, EChip. Different combinations of incubation temperatures and lithium, magnesium, and D-serine concentrations were evaluated to determine the optimum conditions for the detection of heat-injured L. monocytogenes in filter-sterilized whole milk inoculated with selected problematic background microflora. A concentration of 212 mM lithium chloride completely inhibited the growth of Enterococcus faecium while permitting recovery and detection of L. monocytogenes. A concentration of 15.8 mM MgSO4 was found to be optimum for the recovery and detection of L. monocytogenes. A concentration of 140.2 mM D-serine was found to completely inhibit the germination of Bacillus subtilis var. globii spores but not recovery and detection of L. monocytogenes. Under optimum concentrations of LiC1, MgSO4, and D-serine and in the absence of background microflora, the effect of incubation temperature on percentage detection was described by a second-order polynomial model, and 28°C was determined to be optimal. In the presence of background microflora, the effect of incubation temperature on percentage detection of heat-injured cells was described by a third-order polynomial model, and 30°C was found to be optimal. Optimizing the levels of highly specific and selective agents, nutrients, and incubation temperature in one recovery enrichment system dramatically increased the Listeria/background microflora ratio. This resulting medium, optimized PSU (oPSU) broth, greatly improved the detection of heat-injured and nonheat-injured L. monocytogenes by both conventional and molecular methods (Oxoid's Listeria Rapid Test, Gen-Probe's Accuprobe Listeria monocytogenes Culture Identification Test, and Qualicon's BAX for screening Listeria monocytogenes).

Cite

CITATION STYLE

APA

Teo, A. Y. L., Ziegler, G. R., & Knabel, S. J. (2001). Optimizing detection of heat-injured Listeria monocytogenes in pasteurized milk. Journal of Food Protection, 64(7), 1000–1011. https://doi.org/10.4315/0362-028X-64.7.1000

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free