Anodic stripping voltammetry procedure modified for improved accuracy of blood lead analysis

55Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In evaluating the accuracy and reliability of blood lead (PbB) measurements with the Environmental Science Associates Model 3010A Trace Metal Analyzer, intralaboratory comparison demonstrated that use of the operating conditions recommended by the manufacturer resulted in consistently underestimated PbB concentrations < 400 μg/L and overestimated PbB values > 400 μg/L. At PbB concentrations <50 μg/L, measured concentrations were often registered as negative results. However, these negative results could be replicated to within ± 10 μg/L, indicating good precision of the method, but obviously not good accuracy. In addition, lower-than-expected lead (Pb) values were measured in samples containing increased concentrations of copper (Cu), such as may occur in pregnant women. We modified the procedure to eliminate these inaccuracies by substituting manual peakheight measurements for reliance on the integrator and digital display of the instrument. We established the accuracy of the modified procedure by using calibration standards previously quantified by isotope dilution-mass spectroscopy. A quality-control program for monitoring PbB analysis is also described.

Cited by Powered by Scopus

Early exposure to lead and juvenile delinquency

385Citations
N/AReaders
Get full text

The developmental consequences of low to moderate prenatal and postnatal lead exposure: Intellectual attainment in the cincinnati lead study cohort following school entry

243Citations
N/AReaders
Get full text

A rapid Zeeman graphite furnace atomic absorption spectrometric method for the determination of lead in blood

196Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Roda, S. M., Greenland, R. D., Bornschein, R. L., & Hammond, P. B. (1988). Anodic stripping voltammetry procedure modified for improved accuracy of blood lead analysis. Clinical Chemistry, 34(3), 563–567. https://doi.org/10.1093/clinchem/34.3.563

Readers over time

‘12‘14‘15‘16‘18‘19‘23‘2400.250.50.751

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

71%

Professor / Associate Prof. 2

29%

Readers' Discipline

Tooltip

Chemistry 3

50%

Materials Science 1

17%

Pharmacology, Toxicology and Pharmaceut... 1

17%

Social Sciences 1

17%

Save time finding and organizing research with Mendeley

Sign up for free
0