Design guideline for application of earth-toair heat exchanger coupled with solar chimney as a natural heating system

29Citations
Citations of this article
69Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In the present paper, design of solar chimney (SC) and earth-to-air heat exchanger (EAHE) to meet the thermal need of flat buildings are studied regarding adaptive thermal comfort criteria. Investigation on the effects of geometric features shows that the design of SC with the air gap and outlet sizes of 0.2 m and also EAHE with the diameter and length of 0.5 and 25.0 m reveals better performance. Thermal comfort analysis shows that the SC is capable to power the underground heating system during few hours of the sunny days even at the ambient temperature as low as 0°C and the heating demand of 1000 W without needing the auxiliary devices. In addition, the required numbers of SCs and the underground air channels are strongly influenced by environmental outdoor conditions and heating demand of building and are approximately calculated by: room volume/50 and 2 × (room volume/50) + 1, respectively.

Cite

CITATION STYLE

APA

Haghighi, A. P., & Maerefat, M. (2013). Design guideline for application of earth-toair heat exchanger coupled with solar chimney as a natural heating system. International Journal of Low-Carbon Technologies, 10(3), 294–304. https://doi.org/10.1093/ijlct/ctu006