Flow mediated dilation of the brachial artery: An investigation of methods requiring further standardization

97Citations
Citations of this article
130Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In order to establish a consistent method for brachial artery reactivity assessment, we analyzed commonly used approaches to the test and their effects on the magnitude and time-course of flow mediated dilation (FMD), and on test variability and repeatability. As a popular and noninvasive assessment of endothelial function, several different approaches have been employed to measure brachial artery reactivity with B-mode ultrasound. Despite some efforts, there remains a lack of defined normal values and large variability in measurement technique. Methods: Twenty-six healthy volunteers underwent repeated brachial artery diameter measurements by B-mode ultrasound. Following baseline diameter recordings we assessed endothelium-dependent flow mediated dilation by inflating a blood pressure cuff either on the upper arm (proximal) or on the forearm (distal). Results: Thirty-seven measures were performed using proximal occlusion and 25 with distal occlusion. Following proximal occlusion relative to distal occlusion, FMD was larger (16.2 ± 1.2% vs. 7.3 ± 0.9%, p < 0.0001) and elongated (107.2 s vs. 67.8 s, p = 0.0001). Measurement of the test repeatability showed that differences between the repeated measures were greater on average when the measurements were done using the proximal method as compared to the distal method (2.4%; 95% CI 0.5-4.3; p = 0.013). Conclusion: These findings suggest that forearm compression holds statistical advantages over upper arm compression. Added to documented physiological and practical reasons, we propose that future studies should use forearm compression in the assessment of endothelial function. © 2007 Peretz et al; licensee BioMed Central Ltd.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42109Citations
N/AReaders
Get full text

Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis

4312Citations
N/AReaders
Get full text

Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: A report of the international brachial artery reactivity task force

4138Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Assessment of flow-mediated dilation in humans: A methodological and physiological guideline

1180Citations
N/AReaders
Get full text

2010 ACCF/AHA guideline for assessment of cardiovascular risk in asymptomatic adults

1135Citations
N/AReaders
Get full text

2010 ACCF/AHA guideline for assessment of cardiovascular risk in asymptomatic adults: A report of the american college of cardiology foundation/american heart association task force on practice guidelines

567Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Peretz, A., Leotta, D. F., Sullivan, J. H., Trenga, C. A., Sands, F. N., Aulet, M. R., … Kaufman, J. D. (2007). Flow mediated dilation of the brachial artery: An investigation of methods requiring further standardization. BMC Cardiovascular Disorders, 7. https://doi.org/10.1186/1471-2261-7-11

Readers over time

‘09‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 54

64%

Researcher 13

15%

Lecturer / Post doc 10

12%

Professor / Associate Prof. 8

9%

Readers' Discipline

Tooltip

Medicine and Dentistry 45

54%

Sports and Recreations 15

18%

Agricultural and Biological Sciences 13

15%

Engineering 11

13%

Article Metrics

Tooltip
Mentions
References: 1

Save time finding and organizing research with Mendeley

Sign up for free
0