The truth Hertz—synchronization of electroencephalogram signals with physiological waveforms recorded in an intensive care unit

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective. The ability to synchronize continuous electroencephalogram (cEEG) signals with physiological waveforms such as electrocardiogram (ECG), invasive pressures, photoplethysmography and other signals can provide meaningful insights regarding coupling between brain activity and other physiological subsystems. Aligning these datasets is a particularly challenging problem because device clocks handle time differently and synchronization protocols may be undocumented or proprietary. Approach. We used an ensemble-based model to detect the timestamps of heartbeat artefacts from ECG waveforms recorded from inpatient bedside monitors and from cEEG signals acquired using a different device. Vectors of inter-beat intervals were matched between both datasets and robust linear regression was applied to measure the relative time offset between the two datasets as a function of time. Main Results. The timing error between the two unsynchronized datasets ranged between −84 s and +33 s (mean 0.77 s, median 4.31 s, IQR25-4.79 s, IQR75 11.38s). Application of our method improved the relative alignment to within ± 5ms for more than 61% of the dataset. The mean clock drift between the two datasets was 418.3 parts per million (ppm) (median 414.6 ppm, IQR25 411.0 ppm, IQR75 425.6 ppm). A signal quality index was generated that described the quality of alignment for each cEEG study as a function of time. Significance. We developed and tested a method to retrospectively time-align two clinical waveform datasets acquired from different devices using a common signal. The method was applied to 33,911h of signals collected in a paediatric critical care unit over six years, demonstrating that the method can be applied to long-term recordings collected under clinical conditions. The method can account for unknown clock drift rates and the presence of discontinuities caused by clock resynchronization events.

Cite

CITATION STYLE

APA

Goodwin, A. J., Dixon, W., Mazwi, M., Hahn, C. D., Meir, T., Goodfellow, S. D., … Eytan, D. (2023). The truth Hertz—synchronization of electroencephalogram signals with physiological waveforms recorded in an intensive care unit. Physiological Measurement, 44(8). https://doi.org/10.1088/1361-6579/ace49e

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free