Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique

  • Marques F
  • Sato R
  • Chiacchio B
  • et al.
N/ACitations
Citations of this article
26Readers
Mendeley users who have this article in their library.

Abstract

PURPOSE To evaluate the distance, intermediate and near visual acuity of patients with bilateral cataract operated on both eyes corrected for distance in one eye and for near in the fellow eye, as well as, their stereo acuity and their general satisfaction. SETTINGS Hospital de Olhos de São Paulo and Complexo Hospitalar Padre Bento - Guarulhos - São Paulo - Brazil. METHODS This is a prospective study of 76 eyes of 38 patients with bilateral cataract aiming to become spectacle free after surgery. The patients were operated on both eyes; the first eye was corrected for distance and the fellow eye for near vision. The refractive error was programmed between -0.5 D and +0.5 D in the first eye and -2.00 D in the second eye. Patients with preoperative corneal astigmatism equal or higher than 1.0 D were excluded from the study. The uncorrected and best-corrected distant visual acuity (UCDVA, BCDVA) were tested, as well as the uncorrected near visual acuity (UCNVA) and collected at the 3 postoperative months. The Titmus test was performed at the last follow-up. Finally, the modified questionnaire VF-7 was applied and the patient was required to choose, regarding their general satisfaction, between very satisfied, satisfied, or unsatisfied. RESULTS All patients achieved uncorrected distant visual acuity 20/40 or better (mean SE 0.625 D) and uncorrected near visual acuity J3 or better (mean SE -2.0 D), and intermediate visual acuity J3 in 90%. The Titmus test revealed an average of 197' of arc with reduction of stereo acuity in most of patients as expected and 97.3% of patients demonstrated to be satisfied or very satisfied with this technique. CONCLUSION It consists in a viable technique for correction of near, intermediate and distant vision on cataract surgery as demonstrated by the high rate of satisfaction (97.3%) by the modified VF-7 questionnaire, especially when the patient has no access to a multifocal intraocular lens.

Cite

CITATION STYLE

APA

Marques, F. F., Sato, R. M., Chiacchio, B. B., Marques, D. M. V., Barreiro, J., & Caetano, R. L. (2009). Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique. Arquivos Brasileiros de Oftalmologia, 72(2), 164–168. https://doi.org/10.1590/s0004-27492009000200006

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free