Total interleukin-6 in plasma measured by immunoassay

29Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Determinations of total cytokine concentration in biological fluids by immunoassays face two major problems: the biochemical heterogeneity of the analyte and the interference of cytokine-binding proteins. We developed an ultrasensitive enzyme immunoassay for interleukin-6 (IL-6), using monoclonal antibodies and acetylcholinesterase as the tracer enzyme. The antibodies recognized recombinant and glycosylated forms of IL-6 equally. The antibodies measured dimeric recombinant IL-6, yet we could not detect IL-6 oligomers in plasma samples. We investigated the potential interference of soluble IL-6 receptor (sIL-6R), which is present at high concentrations in plasma samples (1 to 2 nmol/L). Heat treatment of the sample obviated the sIL-6R interference. Using calibrators in a plasma matrix, we demonstrated by fractionation, dilution, and recovery experiments that the immunoassay accurately measured total IL-6 in both normal and pathological serum and plasma samples.

Cite

CITATION STYLE

APA

Brailly, H., Montero-Julian, F. A., Zuber, C. E., Flavetta, S., Grassi, J., Houssiau, F., & VanSnick, J. (1994). Total interleukin-6 in plasma measured by immunoassay. Clinical Chemistry, 40(1), 116–123. https://doi.org/10.1093/clinchem/40.1.116

Register to see more suggestions