The spectral irradiance traceability chain at PTB

5Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Spectral irradiance is a fundamental radiometric unit. Its application to measurement results requires qualified traceability to basic units of the international system of units (Système international d'unités, SI). The Physikalisch-Technische Bundesanstalt (PTB) is amongst other national metrological institutes (NMIs) responsible for the realization, maintenance and dissemination of various radiometric and photometric units based on and traceable to national standards. The unit of spectral irradiance is realized and represented by a blackbody-radiator as the national primary standard of the PTB. Based on Planck's radiation law, the irradiance is calculated and realized for any wavelength taking into account the exact knowledge of the radiation temperature and the geometrical parameters. Using a double-monochromator-based spectroradiometer system, secondary standard lamps can be calibrated by direct comparison to the blackbody-radiator (substitution method). These secondary standard lamps are then used at the PTB to calibrate standard lamps of customers. The customers themselves use these so-called transfer standards to calibrate their working standard lamps. These working standards are then used to calibrate own spectroradiometers or sources. This rather complex calibration chain is a common procedural method that for the customers generally leads to satisfying measurement results on site. Nevertheless, the standard lamps in use have to fulfill highest requirements concerning stability and reproducibility. Only this allows achieving comparably low transfer measurement uncertainties, which occur at each calibration step. Thus, the PTB is constantly investigating the improvement and further development of transfer standards and measurement methods for various spectral regions. The realization and dissemination of the spectral irradiance using the blackbody-radiator at the PTB is accomplished with worldwide approved minimized measurement uncertainties confirmed by international intercomparisons among NMIs. Ultimately, the spectral irradiance can be realized with expanded measurement uncertainties of far less than 1 % over a wide spectral range. Thus, for customers with high demands on low measurement uncertainties, it is possible to calibrate their working standards directly against the blackbody-radiator, taking into account the higher necessary effort. In special cases it is possible to calibrate the customer's spectroradiometric facilities directly in front of the blackbody-radiator. In the context of the European Metrology Research Project Traceability for surface spectral solar ultraviolet radiation, the traceability chain will be improved and adapted. © 2013 AIP Publishing LLC.

References Powered by Scopus

Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer

103Citations
N/AReaders
Get full text

SOLAR/SOLSPEC: Scientific objectives, instrument performance and its absolute calibration using a blackbody as primary standard source

70Citations
N/AReaders
Get full text

Precision blackbody sources for radiometric standards

51Citations
N/AReaders
Get full text

Cited by Powered by Scopus

SOLAR-ISS: A new reference spectrum based on SOLAR/SOLSPEC observations

80Citations
N/AReaders
Get full text

Solar and infrared radiation measurements, second edition

17Citations
N/AReaders
Get full text

Overview of the study for transfer radiometer with spectral standard calibration and transferring technology

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sperfeld, P., Pape, S., & Nevas, S. (2013). The spectral irradiance traceability chain at PTB. In AIP Conference Proceedings (Vol. 1531, pp. 801–804). https://doi.org/10.1063/1.4804891

Readers over time

‘19‘20‘21‘2302468

Readers' Seniority

Tooltip

Researcher 3

60%

Lecturer / Post doc 1

20%

PhD / Post grad / Masters / Doc 1

20%

Readers' Discipline

Tooltip

Physics and Astronomy 3

60%

Engineering 2

40%

Save time finding and organizing research with Mendeley

Sign up for free
0