Concentration-dependent Differences in Urinary Iodine Measurements Between Inductively Coupled Plasma Mass Spectrometry and the Sandell-Kolthoff Method

9Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A large amount of historical data regarding urinary iodine concentration (UIC) were measured with the Sandell-Kolthoff (S-K) method for iodine nutrition surveillance. The congruence in urinary iodine measurements between inductively coupled plasma mass spectrometry (ICP-MS) and the S-K method has been debated. A total of 2064 adult urine samples were included in the present study. The UIC measurement results obtained simultaneously by standardized ICP-MS and the S-K method were analyzed. The UIC obtained with ICP-MS was significantly higher than that obtained with the S-K method (158 μg/L vs. 148 μg/L, p < 0.001). The Bland-Altman difference plot showed a small but significant mean difference of 6.12 μg/L between the two methods. The stratified analysis showed that the correlation coefficient was higher in the UIC < 300 μg/L group than the UIC ≥ 300 μg/L group (0.93 vs. 0.88, p = 0.0001). The mean difference between the S-K and ICP-MS methods was positively correlated with the UIC. The ICP-MS and S-K methods were comparable when the UIC was less than 300 μg/L; however, UIC values between 300 and 600 μg/L should be compared with caution after considering the research objective. We do not suggest comparing UICs obtained from the ICP-MS and S-K methods in iodine monitoring studies if the UIC is greater than 600 μg/L.

References Powered by Scopus

Prevalence of diabetes recorded in mainland China using 2018 diagnostic criteria from the American Diabetes Association: National cross sectional study

1404Citations
N/AReaders
Get full text

Effect of iodine intake on thyroid diseases in China

663Citations
N/AReaders
Get full text

Micro determination of iodine by a catalytic method

488Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The Impact of Iodine Concentration Disorders on Health and Cancer

24Citations
N/AReaders
Get full text

Changing Iodine Status and the Incidence of Thyroid Disease in Mainland China: A Prospective 20-Year Follow-Up Study

16Citations
N/AReaders
Get full text

Ultrasensitive iodide detection in biofluids based on hot electron-induced reduction of p-Nitrothiophenol on Au@Ag core-shell nanoparticles

12Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Li, Y., Ding, S., Han, C., Liu, A., Shan, Z., Teng, W., & Mao, J. (2021). Concentration-dependent Differences in Urinary Iodine Measurements Between Inductively Coupled Plasma Mass Spectrometry and the Sandell-Kolthoff Method. Biological Trace Element Research, 199(7), 2489–2495. https://doi.org/10.1007/s12011-020-02381-8

Readers over time

‘20‘21‘22‘23‘2402468

Readers' Seniority

Tooltip

Professor / Associate Prof. 2

29%

PhD / Post grad / Masters / Doc 2

29%

Researcher 2

29%

Lecturer / Post doc 1

14%

Readers' Discipline

Tooltip

Chemistry 2

40%

Chemical Engineering 1

20%

Materials Science 1

20%

Pharmacology, Toxicology and Pharmaceut... 1

20%

Save time finding and organizing research with Mendeley

Sign up for free
0