Diffusion tensor imaging of the brachial plexus: A comparison between readout-segmented and conventional single-shot echo-planar imaging

11Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Diffusion tensor imaging (DTI) adds functional information to morphological magnetic resonance neurography (MRN) in the assessment of the brachial nerve plexus. To determine the most appropriate pulse sequence in scan times suited for diagnostic imaging in clinical routine, we compared image quality between simultaneous multi-slice readout-segmented (rs-DTI) and conventional single-shot (ss-DTI) echo-planar imaging techniques. Methods: Institutional Review Board (IRB) approved study including 10 healthy volunteers. The supraclavicular brachial plexus, covering the nerve roots and trunks from C5 to C7, was imaged on both sides with rs-DTI and ss-DTI. Both sequences were acquired in scan times <7 min with b-values of 900 s/mm2 and with isotropic spatial resolution. Results: In rs-DTI image, the overall quality was significantly better and distortion artifacts were significantly lower (P = 0.001-0.002 and P = 0.001-0.002, respectively) for both readers. In ss-DTI, a trend toward lower degree of ghosting and motion artifacts was elicited (reader 1, P = 0.121; reader 2, P = 0.264). No significant differences between the two DTI techniques were found for signal-to-noise ratios (SNR), contrast- to-noise ratios (CNR) and fractional anisotropy (FA) (P ≥ 0.475, P ≥ 0.624, and P ≥ 0.169, respectively). Interreader agreement for all examined parameters and all sequences ranged from intraclass correlation coefficient (ICC) 0.064 to 0.905 and Kappa 0.40 to 0.851. Conclusion: Incomparable acquisition times rs-DTI showed higher image quality and less distortion artifacts than ss-DTI. The trend toward a higher degree of ghosting and motion artifacts in rs-DTI did not deteriorate image quality to a significant degree. Thus, rs-DTI should be considered for functional MRN of the brachial plexus.

Cite

CITATION STYLE

APA

Ho, M. J., Ciritsis, A., Manoliu, A., Stieltjes, B., Marcon, M., Andreisek, G., & Kuhn, F. P. (2019). Diffusion tensor imaging of the brachial plexus: A comparison between readout-segmented and conventional single-shot echo-planar imaging. Magnetic Resonance in Medical Sciences, 18(2), 150–157. https://doi.org/10.2463/mrms.mp.2018-0004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free