Comparison of survival time of Hawley and Vacuum-formed retainers in orthhodontic patients– a randomized clinical trial

  • Moslemzadeh S
  • Sohrabi A
  • Rafighi A
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Background: Maintaining the results of orthodontic treatment and keeping the teeth in the corrected position is a great challenge in orthodontics. This study aimed to compare the survival time of three types of retainers including Hawley, 1-mm Vacuum-Formed (VF), and 1.5-mm VF within 6-month period. Methods: In this randomized clinical study, 152 patients were allocated into three groups to receive one type of the retainers. They were visited 1, 3, and 6 months after retainer delivery and checked for breakage, loss, local perforation, and discoloration from the patient's and clinician's point of view as indicators of failure. Chi-square and Fisher's exact tests were used as appropriated. Result: The results revealed that breakage was among the main reasons of failure of retainers within 6 months, which was statistically significantly different between Hawley and VF retainers, as well as between 1-mm and 1.5-mm VF retainers in the three intervals (p<0.05). Concerning the loss of retainer and discoloration from the clinician's point of view, there was no significant difference between the retainers in any interval (p>0.05). Assessing the discoloration from the patient's point of view revealed statistically significant differences between Hawley and VF retainers within the first month; however, the difference was not significant at the third and sixth months (p<0.05). The difference between the two thicknesses of VF retainer was not significant in any interval (p>0.05). By the end of the sixth month, some of the VF retainers had perforation; while, perforation was not observed in Hawley retainers.Conclusion: Considering the higher breakage rate of 1-mm VF, 1.5-mm VF seems the retainer if choice.Key words: survival time; retainer; Hawley retainer; Vacuum-formed retainer;

Cite

CITATION STYLE

APA

Moslemzadeh, S. H., Sohrabi, A., Rafighi, A., Ghojazadeh, M., & Rahmanian, S. (2017). Comparison of survival time of Hawley and Vacuum-formed retainers in orthhodontic patients– a randomized clinical trial. Advances in Bioscience and Clinical Medicine, 5(1), 7. https://doi.org/10.7575/aiac.abcmed.17.05.01.02

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free