This paper proposes a novel and rapid calibration-free wavelength modulation spectroscopy algorithm based on even-order harmonics. The proposed algorithm, analytically deduced from Voigt line-shape function, only involves simple algebraic operations to describe the actual gas absorption spectra, thus eliminating the time-consuming simulations and line-shape fitting procedures adopted in traditional algorithms. Instead of acquiring the entirely scanned absorption line-shape, the proposed technique only requires extraction of the peak values of the harmonics. This characteristic significantly benefits gas diagnosis at elevated pressure and/or temperature, in which the entirely scanned absorption is very difficult to be obtained due to the broadened line-shapes. The proposed algorithm is validated by both numerical simulation and condition-controlled experiment, indicating millisecond-level calculation of gas parameters with the relative error less than 4% in the experiments.
CITATION STYLE
Wang, Y., Zhou, B., & Liu, C. (2021). Calibration-free wavelength modulation spectroscopy based on even-order harmonics. Optics Express, 29(17), 26618. https://doi.org/10.1364/oe.432361