Real-time simulator for designing electron dual scattering foil systems

5Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The purpose of this work was to develop a user friendly, accurate, real-time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator allows for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator also is a powerful educational tool. The simulator consists of an analytical algorithm for calculating electron fluence and X-ray dose and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi-Eyges multiple Coulomb scattering theory with the reduced Gaussian formalism for scattering powers. The simulator also estimates central-axis and off-axis X-ray dose arising from the dual foil system. Once the geometry of the accelerator is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scattering foil material and Gaussian shape (thickness and sigma), and beam energy. The off-axis electron relative fluence or total dose profile and central-axis X-ray dose contamination are computed and displayed in real time. The simulator was validated by comparison of off-axis electron relative fluence and X-ray percent dose profiles with those calculated using EGSnrc MC. Over the energy range 7-20MeV, using present foils on an Elekta radiotherapy accelerator, the simulator was able to reproduce MC profiles to within 2% out to 20 cm from the central axis. The central-axis X-ray percent dose predictions matched measured data to within 0.5%. The calculation time was approximately 100 ms using a single Intel 2.93GHz processor, which allows for real-time variation of foil geometrical parameters using slider bars. This work demonstrates how the user-friendly GUI and real-time nature of the simulator make it an effective educational tool for gaining a better understanding of the effects that various system parameters have on a relative dose profile. This work also demonstrates a method for using the simulator as a design tool for creating custom dual scattering foil systems in the clinical range of beam energies (6-20 MeV).

References Powered by Scopus

Clinical electron-beam dosimetry: Report of AAPM Radiation Therapy Committee Task Group No. 25

396Citations
N/AReaders
Get full text

Multiple scattering with energy loss [5]

267Citations
N/AReaders
Get full text

Recommendations for clinical electron beam dosimetry: Supplement to the recommendations of Task Group 25

127Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Calorimeter for Real-Time Dosimetry of Pulsed Ultra-High Dose Rate Electron Beams

30Citations
N/AReaders
Get full text

Radiation leakage dose from Elekta electron collimation system

5Citations
N/AReaders
Get full text

Very high-energy electron dose calculation using the Fermi-Eyges theory of multiple scattering and a simplified pencil beam model

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Carver, R. L., Hogstrom, K. R., Price, M. J., LeBlanc, J. D., & Pitcher, G. M. (2014). Real-time simulator for designing electron dual scattering foil systems. Journal of Applied Clinical Medical Physics, 15(6), 323–342. https://doi.org/10.1120/jacmp.v15i6.4849

Readers' Seniority

Tooltip

Professor / Associate Prof. 1

33%

Lecturer / Post doc 1

33%

PhD / Post grad / Masters / Doc 1

33%

Readers' Discipline

Tooltip

Physics and Astronomy 2

100%

Save time finding and organizing research with Mendeley

Sign up for free