Abstract

Quantifying corrosion damage is vital for the petrochemical industry, and guided wave tomography can provide thickness maps of such regions by transmitting guided waves through these areas and capturing the scattering information using arrays. The dispersive nature of the guided waves enables a reconstruction of wave velocity to be converted into thickness. However, existing approaches have been shown to be limited in in-plane resolution, significantly short of that required to accurately image a defect target of three times the wall thickness (i.e. 3 T) in each in-plane direction. This is largely due to the long wavelengths of the fundamental modes commonly used, being around 4 T for both A0 and S0 at the typical operation points. In this work, the suitability of the first-order shear-horizontal guided wave mode, SH1, has been investigated to improve the resolution limit. The wavelength at the desired operating point is significantly shorter, enabling an improvement in resolution of around 2.4 times. This is first verified by realistic finite-element simulations and then validated by experimental results, confirming the improved resolution limit can now allow defects of maximum extent 3T-by-3T to be reliably detected and sized, i.e. a long-pursued goal of guided wave tomography has been achieved.

Cite

CITATION STYLE

APA

Zimmermann, A. A. E., Huthwaite, P., & Pavlakovic, B. (2021). High-resolution thickness maps of corrosion using SH1 guided wave tomography. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 477(2245). https://doi.org/10.1098/rspa.2020.0380

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free