Flow-injection coulometric detection based on ion transfer and its application to the determination of chlorpromazine

9Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowing solution and an inner aqueous electrolyte solution. Two pairs of electrodes, each pair formed by a reference electrode and a working electrode, are used, one pair in each solution. The potential between the reference electrodes was controlled by a four-electrode potentiostat with ohmic drop compensation. A potential step capable of producing the transfer of the chlorpromazine ion into the membrane was applied during the passage of a wide portion of sample plug through the cell and the corresponding quantity of the electricity was measured. In the selected conditions, a linear relationship was observed between the quantity of electricity and chlorpromazine concentrations over a range of 1 × 10-6 - 1 × 10-4 M. The detection limit was 2 × 10-7 M. Good repeatability and between-day reproducibility was obtained. No interference was observed on the part of some common ions and pharmaceutical excipients. The method proposed was applied satisfactorily to the determination of chlorpromazine in pharmaceuticals and human urine.

References Powered by Scopus

Electrochemistry at the interface between two immiscible electolyte solutions (IUPAC technical report)

329Citations
N/AReaders
Get full text

Electrochemistry at liquid/liquid interfaces: Methodology and potential applications

274Citations
N/AReaders
Get full text

Properties of PVC based membranes used in ion-selective electrodes

251Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Opportunities and challenges of using ion-selective electrodes in environmental monitoring and wearable sensors

117Citations
N/AReaders
Get full text

Electrochemical Methods to Evaluate the Antioxidant Activity and Capacity of Foods: A Review

57Citations
N/AReaders
Get full text

Electrochemically exfoliated porous WS<inf>2</inf> nanosheets: A potential electrochemical sensing platform for chlorpromazine detection

20Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ortuño, J. A., Gil, A., & Sánchez-Pedreño, C. (2008). Flow-injection coulometric detection based on ion transfer and its application to the determination of chlorpromazine. Sensors, 8(6), 3678–3688. https://doi.org/10.3390/s8063678

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

57%

Professor / Associate Prof. 3

43%

Readers' Discipline

Tooltip

Chemistry 6

75%

Agricultural and Biological Sciences 1

13%

Social Sciences 1

13%

Article Metrics

Tooltip
Mentions
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free