MIRSIG position paper: the use of image registration and fusion algorithms in radiotherapy

9Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

The report of the American Association of Physicists in Medicine (AAPM) Task Group No. 132 published in 2017 reviewed rigid image registration and deformable image registration (DIR) approaches and solutions to provide recommendations for quality assurance and quality control of clinical image registration and fusion techniques in radiotherapy. However, that report did not include the use of DIR for advanced applications such as dose warping or warping of other matrices of interest. Considering that DIR warping tools are now readily available, discussions were hosted by the Medical Image Registration Special Interest Group (MIRSIG) of the Australasian College of Physical Scientists & Engineers in Medicine in 2018 to form a consensus on best practice guidelines. This position statement authored by MIRSIG endorses the recommendations of the report of AAPM task group 132 and expands on the best practice advice from the ‘Deforming to Best Practice’ MIRSIG publication to provide guidelines on the use of DIR for advanced applications.

References Powered by Scopus

The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy

1314Citations
N/AReaders
Get full text

Medical image registration

1261Citations
N/AReaders
Get full text

Errors and Margins in Radiotherapy

1222Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Review and recommendations on deformable image registration uncertainties for radiotherapy applications

20Citations
N/AReaders
Get full text

Patient-specific quality assurance for deformable IMRT/IMPT dose accumulation: Proposition and validation of energy conservation based validation criterion

7Citations
N/AReaders
Get full text

Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lowther, N., Louwe, R., Yuen, J., Hardcastle, N., Yeo, A., & Jameson, M. (2022). MIRSIG position paper: the use of image registration and fusion algorithms in radiotherapy. Physical and Engineering Sciences in Medicine, 45(2), 421–428. https://doi.org/10.1007/s13246-022-01125-3

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

50%

Professor / Associate Prof. 2

25%

Lecturer / Post doc 1

13%

Researcher 1

13%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

50%

Nursing and Health Professions 2

25%

Chemical Engineering 1

13%

Physics and Astronomy 1

13%