Background: Massive bone defects of the acetabulum with pelvic discontinuity are one of the major problems in revision total hip arthroplasty. Several techniques have been described for repair of acetabular defect; however, reconstruction of acetabulum with massive bone defect is still a major problem. We describe a patient who required four revision total hip arthroplasty during a 24-year period. Findings: The acetabulum with pelvic discontinuity was successfully reconstructed by stabilization of the posterior column with a plate commonly used for fracture treatment, and stabilization of the anterior column by reinforcement device commonly used for acetabular reconstruction. Fixation of both acetabular columns provided significant improvement of component stability. Conclusions: In the case of pelvic discontinuity with massive acetabular bone defect, reconstruction by stabilizing both acetabular columns using reconstruction plate and KT plate is one of the better surgical options.
CITATION STYLE
Kokubo, Y., Oki, H., Takeura, N., Negoro, K., Takeno, K., Miyazaki, T., … Nakajima, H. (2016). Reconstruction of acetabulum in revision total hip arthroplasty for pelvic discontinuity: report of a difficult case requiring four revision arthroplasty. SpringerPlus, 5(1). https://doi.org/10.1186/s40064-016-2247-9