Fractal circuit sensors enable rapid quantification of biomarkers for donor lung assessment for transplantation

31Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.

Abstract

Biomarker profiling is being rapidly incorporated in many areas of modern medical practice to improve the precision of clinical decision-making. This potential improvement, however, has not been transferred to the practice of organ assessment and transplantation because previously developed gene-profiling techniques require an extended period of time to perform, making them unsuitable in the time-sensitive organ assessment process. We sought to develop a novel class of chip-based sensors that would enable rapid analysis of tissue levels of preimplantation mRNA markers that correlate with the development of primary graft dysfunction (PGD) in recipients after transplant. Using fractal circuit sensors (FraCS), three-dimensional metal structures with large surface areas, we were able to rapidly (<20 min) and reproducibly quantify small differences in the expression of interleukin-6 (IL-6), IL-10, and ATP11B mRNA in donor lung biopsies. A proof-of-concept study using 52 human donor lungs was performed to develop a model that was used to predict, with excellent sensitivity (74%) and specificity (91%), the incidence of PGD for a donor lung. Thus, the FraCS-based approach delivers a key predictive value test that could be applied to enhance transplant patient outcomes. This work provides an important step toward bringing rapid diagnostic mRNA profiling to clinical application in lung transplantation.

References Powered by Scopus

Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA

992Citations
N/AReaders
Get full text

Ischemia-reperfusion-induced lung injury.

827Citations
N/AReaders
Get full text

Cyclic and Differential Pulse Voltammetric Behavior of Reactants Confined to the Electrode Surface

770Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules

787Citations
N/AReaders
Get full text

DNA Nanotechnology-Enabled Interfacial Engineering for Biosensor Development

108Citations
N/AReaders
Get full text

Chemistry-driven approaches for ultrasensitive nucleic acid detection

96Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sage, A. T., Besant, J. D., Mahmoudian, L., Poudineh, M., Bai, X., Zamel, R., … Kelley, S. O. (2015). Fractal circuit sensors enable rapid quantification of biomarkers for donor lung assessment for transplantation. Science Advances, 1(7). https://doi.org/10.1126/sciadv.1500417

Readers over time

‘15‘16‘17‘18‘19‘20‘21‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 16

62%

Professor / Associate Prof. 5

19%

Researcher 4

15%

Lecturer / Post doc 1

4%

Readers' Discipline

Tooltip

Chemistry 11

38%

Engineering 8

28%

Medicine and Dentistry 6

21%

Agricultural and Biological Sciences 4

14%

Article Metrics

Tooltip
Mentions
News Mentions: 1
Social Media
Shares, Likes & Comments: 6

Save time finding and organizing research with Mendeley

Sign up for free
0