Abstract

A compact active x-ray beamstop has been developed for the SWING beamline at Synchrotron SOLEIL with two main functions, blocking the x-ray beam directly transmitted by the sample to protect the Dectris EigerX4M 2D detector and monitoring its intensity. The beamstop is composed of a sensor inserted in a well of tungsten carbide. The sensor is based on a piece of free-standing single crystal chemical vapor deposited diamond used in the ionization chamber mode. The beamstop has been installed on the beamline detector stage within the detection vacuum chamber, just upstream of the large 2D detector. The intensity monitoring performance (rms noise over signal) is shown to be better than 0.06% and the linearity is shown to be better than 2% for over more than five decades. The beamstop has been calibrated between 5 and 16 keV to provide the photon flux measurements in absolute units (ph/s). The specific design of the beamstop increases the small-angle x-ray scattering q-range by a factor of 1.5 in the low angle side, as compared to the previous active beamstop, based on a more standard commercial Si diode. The beamstop has been available for three years for SWING user operation (5-17 keV). It is fully compatible with the different beamline operating modes and fluxes, except in the microbeam mode, where the very divergent beam becomes too large at the beamstop position, and the previous, larger, beamstop is then more appropriate.

References Powered by Scopus

X-ray interactions: Photoabsorption, scattering, transmission, and reflection at E = 50-30, 000 eV, Z = 1-92

5645Citations
N/AReaders
Get full text

Single crystal diamond photodiode for soft X-ray radiometry

48Citations
N/AReaders
Get full text

A brief survey of state-of-the-art BioSAXS

44Citations
N/AReaders
Get full text

Cited by Powered by Scopus

BioSAXS on the SWING beamline at Synchrotron SOLEIL

49Citations
N/AReaders
Get full text

Influence of defects on the tensile behaviour of flax fibres: Cellulose microfibrils evolution by synchrotron X-ray diffraction and finite element modelling

16Citations
N/AReaders
Get full text

Exploring the effect of relative humidity on dynamic evolution of flax fibre's microfibril angle through in situ tensile tests under synchrotron X-ray diffraction

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Desjardins, K., Pomorski, M., Bizien, T., Thureau, A., Menneglier, C., & Pérez, J. (2021). An active x-ray beamstop based on single crystal CVD diamond at beamline SWING. Review of Scientific Instruments, 92(4). https://doi.org/10.1063/5.0048326

Readers over time

‘21‘22‘24‘2500.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

44%

Researcher 4

44%

Professor / Associate Prof. 1

11%

Readers' Discipline

Tooltip

Physics and Astronomy 3

43%

Materials Science 2

29%

Engineering 1

14%

Biochemistry, Genetics and Molecular Bi... 1

14%

Save time finding and organizing research with Mendeley

Sign up for free
0