Three-dimensional echocardiographic quantification of the left-heart chambers using an automated adaptive analytics algorithm: Multicentre validation study

105Citations
Citations of this article
92Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims Although recommended by current guidelines, adoption of three-dimensional echocardiographic (3DE) chamber quantification in clinical practice has lagged because of time-consuming analysis. We recently validated an automated algorithm that measures left atrial (LA) and left ventricular (LV) volumes and ejection fraction (EF). This study aimed to determine the accuracy and reproducibility of these measurements in a multicentre setting. Methods and results 180 patients underwent 3DE imaging (Philips) at six sites. Images were analysed using automated HeartModel (HM) software with endocardial border correction when necessary and by manual tracing. Measurements were performed by each site and by the Core Laboratory (CL) as the reference. Inter-technique comparisons included HM measurements by the sites against manual tracing by CL, and showed strong correlations (r-values: LVEDV: 0.97, LVESV: 0.97, LVEF: 0.88, LAV: 0.96), with the automated technique slightly underestimating LV volumes (biases: LVEDV: -14 ± 20 ml, LVESV: -6 ± 20 ml), LVEF (-2 ± 7%) and LAV (-9 ± 10 ml). Intra-technique comparisons included HM measurements by the sites against CL, with and without corrections. Corrections were unnecessary or minimal in most patients, and improved the measurements only modestly. Comparisons without corrections showed perfect agreement for all parameters. With corrections, correlations were better (r-values: LVEDV: 0.99, LVESV: 0.99, LVEF: 0.94, LAV: 0.99) and biases (LVEDV: -8 ± 12 ml, LVESV: -6 ± 12 ml, LVEF: 1 ± 5%, LAV: -10 ± 6 ml) smaller than in inter-technique comparison. All automated measurements with corrections were more reproducible than manual measurements. Conclusion Automated 3DE analysis of left-heart chambers is an accurate alternative to conventional manual methodology, which yields almost the same values across laboratories and is more reproducible. This technique may contribute towards full integration of 3DE quantification into clinical routine. Published on behalf of the European Society of Cardiology. All rights reserved.

Cite

CITATION STYLE

APA

Medvedofsky, D., Mor-Avi, V., Amzulescu, M., Fernández-Golfín, C., Hinojar, R., Monaghan, M. J., … Lang, R. M. (2018). Three-dimensional echocardiographic quantification of the left-heart chambers using an automated adaptive analytics algorithm: Multicentre validation study. European Heart Journal Cardiovascular Imaging, 19(1), 47–58. https://doi.org/10.1093/ehjci/jew328

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free