Transcatheter aortic valve replacement for bicuspid aortic valve stenosis with first- and new-generation bioprostheses: a systematic review and meta-analysis

  • Ueshima D
  • Nai Fovino L
  • Brener S
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve re- placement (TAVR) randomized trials. Methods: With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker im- plantation, vascular complications and 1-year mortality. Results: Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR=1.13; 95% CI: 0.88-1.46, p=0.33) and 1- year mortality (OR=1.02; 95% CI: 0.77-1.37, p=0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR=2.35; 95% CI: 1.30- 4.23, p=0.005), implantation of a second valve (OR=2.06; 95% CI: 1.31- 3.25; p=0.002), moderate/severe paravalvular leakage (PVL) (OR=1.67; 95% CI: 1.29-2.17; p=0.0001) and device failure (OR=1.26; 95% CI: 1.02- 1.56; p=0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture. Conclusions: BAV patients treated with TAVR had similar 30-day and 1- year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conver- sion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV.

Cite

CITATION STYLE

APA

Ueshima, D., Nai Fovino, L. N. F., Brener, S. J. B., Pavei, A. P., Fraccaro, C. F., Napodano, M. N., & Tarantini, G. T. (2020). Transcatheter aortic valve replacement for bicuspid aortic valve stenosis with first- and new-generation bioprostheses: a systematic review and meta-analysis. European Heart Journal, 41(Supplement_2). https://doi.org/10.1093/ehjci/ehaa946.1927

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free