Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study

  • Jaillette E
  • Zerimech F
  • De Jonckheere J
  • et al.
N/ACitations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The primary objective of this study was to determine the efficiency of a pneumatic device in controlling cuff pressure (Pcuff) in patients intubated with polyurethane-cuffed tracheal tubes. Secondary objectives were to determine the impact of continuous control of Pcuff, and cuff shape on microaspiration of gastric contents. Methods: Prospective randomized controlled study. All patients requiring intubation and mechanical ventilation > =48 h were eligible. The first 32 patients were intubated with tapered polyurethane-cuffed, and the 32 following patients were intubated with cylindrical polyurethane-cuffed tracheal tubes. Patients randomly received 24 h of continuous control of Pcuff using a pneumatic device (Nosten(R)), and 24 h of routine care of Pcuff using a manometer. Target Pcuff was 25 cmH2O. Pcuff was continuously recorded, and pepsin was quantitatively measured in all tracheal aspirates during these periods. Results: The pneumatic device was efficient in controlling Pcuff (med [IQ] 26 [24, 28] vs 22 [20, 28] cmH2O, during continuous control of Pcuff and routine care, respectively; p = 0.017). In addition, percentage of patients with underinflation (31 % vs 68 %) or overinflation (53 % vs 100 %) of tracheal cuff, and percentage of time spent with underinflation (0.9 [0, 17] vs 14 % [4, 30]) or overinflation (0 [0, 2] vs 32 % [9, 54]) were significantly (p < 0.001) reduced during continuous control of Pcuff compared with routine care.No significant difference was found in microaspiration of gastric content between continuous control of Pcuff compared with routine care, or between patients intubated with tapered compared with cylindrical polyurethane-cuffed tracheal tubes. Conclusion: The pneumatic device was efficient in controlling Pcuff in critically ill patients intubated with polyurethane-cuffed tracheal tubes.The study was registered at clinicaltrial.gov (NCT01351259).

Cite

CITATION STYLE

APA

Jaillette, E., Zerimech, F., De Jonckheere, J., Makris, D., Balduyck, M., Durocher, A., … Nseir, S. (2013). Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study. BMC Anesthesiology, 13(1). https://doi.org/10.1186/1471-2253-13-50

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free