Study design: Disk material removed (DMR) during L4-5 and L5-S1 transforaminal lumbar interbody fusion (T-LIF) surgery was compared to the corresponding bone graft (BG) volumes inserted at the time of fusion. A novel BG delivery tool (BGDT) was used to apply the BG. In order to establish the percentage of DMR during T-LIF, it was compared to DMR during anterior diskectomy (AD). This study was performed prospectively. Summary of background data: Minimal information is available as to the volume of DMR during a T-LIF procedure, and the relationship between DMR and BG delivered is unknown. BG insertion has been empiric and technically challenging. Since the volume of BG applied to the prepared disk space likely impacts the probability of arthrodesis, an investigation is justified. Methods: A total of 65 patients with pathology at L4-5 and/or L5-S1 necessitating fusion were treated with a minimally invasive T-LIF procedure. DMR was volumetrically measured during disk space preparation. BG material consisting of local autograft, BG extender, and bone marrow aspirate were mixed to form a slurry. BG slurry was injected into the disk space using a novel BGDT and measured volumetrically. An additional 29 patients who were treated with L5-S1 AD were compared to L5-S1 T-LIF DMR to determine the percent of T-LIF DMR relative to AD. Results: DMR volumes averaged 3.6±2.2 mL. This represented 34% of the disk space relative to AD. The amount of BG delivered to the disk spaces was 9.3±3.2 mL, which is 2.6±2.2 times the amount of DMR. The BGDT allowed uncomplicated filling of the disk space in,1 minute. Conclusion: The volume of DMR during T-LIF allows for a predictable volume of BG delivery. The BGDT allowed complete filling of the entire prepared disk space. The T-LIF diskectomy debrides 34% of the disk relative to AD.

Cite

CITATION STYLE

APA

Kleiner, J. B., Kleiner, H. M., John Grimberg, E., & Throlson, S. J. (2016). Evaluation of a novel tool for bone graft delivery in minimally invasive transforaminal lumbar interbody fusion. Medical Devices: Evidence and Research, 9, 105–114. https://doi.org/10.2147/MDER.S100098

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free