Toward quantitative fast diffusion kurtosis imaging with b-values chosen in consideration of signal-to-noise ratio and model fidelity:

2Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Diffusion kurtosis (DK) imaging is a variant of conventional diffusion magnetic resonance (MR) imaging that allows assessment of non-Gaussian diffusion. Fast DK imaging expedites the procedure by decreasing both scan time (acquiring the minimally required number of b-values) and computation time (obviating least-square curve fitting). This study aimed to investigate the applicability of fast DK imaging for both cerebral gray matter and white matter as a quantitative method. Methods: Seventeen healthy volunteers were recruited and each provided written informed consent before participation. On a 3-Tesla clinical MR system, diffusion imaging was performed with 12 b-values ranging from 0 to 4000 s/mm2. Diffusion encoding was along three orthogonal directions (slice selection, phase encoding, and frequency encoding) in separate series. Candidate b-values were chosen by first determining the maximum b-value (bmax) in the context of signal-to-noise ratio and then assessing the model fidelity for all b-value combinations within bmax. Diffusion coefficient (D) and diffusion kurtosis coefficient (K) were derived from these candidates and assessed for their dependence on b-value combination. Results: Our data suggested bmax to be 2200 s/mm2 as a trade-off between the percentage (~80%) of voxels statistically detectable against background and the sensitivity to non-Gaussian diffusion in both gray matter and white matter. The measurement dependence on b-value was observed predominantly in areas with a considerable amount of cerebrospinal fluid. In most gray matter and white matter, b-value combinations do not cause statistical difference in the calculated D and K. Conclusions: For fast DK imaging to be quantitatively applicable in both gray matter and white matter, bmax should be chosen to ensure adequate signal-to-noise ratio in the majority of gray/white matter and the two nonzero b-values should be chosen in consideration of model fidelity to mitigate the dependence of derived indices on b-values.

Cite

CITATION STYLE

APA

Kuo, Y. S., Yang, S. C., Chung, H. W., & Wu, W. C. (2018). Toward quantitative fast diffusion kurtosis imaging with b-values chosen in consideration of signal-to-noise ratio and model fidelity: Medical Physics, 45(2), 605–612. https://doi.org/10.1002/mp.12711

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free