Exposure to anesthetic gases and Parkinson's disease: A case report

12Citations
Citations of this article
50Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The administration of anesthetics determines depression of the central nervous system and general anesthesia by inhalation may cause an environmental pollution of the operating rooms. It may therefore conceive a possible occupational etiology of Parkinson's Disease (PD).Case presentation: In a Caucasian male aged 59 years, PD was diagnosed by brain scans with a presynaptic radioactive tracer of the dopaminergic system. Family history was negative for Parkinson's disease or essential tremor. He was a smoker, a moderate consumer of coffee and alcohol, and never exposed to pesticides/metals. For 30 years (since the age of 29 until today), he worked as an anesthesiologist in private clinics in the Veneto (Northern Italy), exposed to anesthetic gases. The time elapsed from first exposure to onset of disease is 22 years, fulfilling the requirement of the induction/latency period. A literature search demonstrated unacceptable levels of anesthetic gases in public hospitals of the Veneto region from 1990 to 1999. This exposure was presumably high also in private hospitals of the region until at least 2007, when an overexposure to sevoflurane was repeatedly measured in this patient. The association between occupational exposure to anesthetic gases and risk of Parkinson's disease was supported by a case-control study (reporting a two-fold increase in the risk of PD associated with a clinical history of general anesthesia) and a cohort study comparing mortality from PD between US anesthesiologists and internists (showing a statistically significant excess (p=0.01) in anesthesiologists compared to internists). Numerous recent mechanistic studies (in vitro essays and in vivo short-term studies) strengthened the association between exposure to anesthetic gases (nitrous oxide, halothane, isoflurane, levoflurane) and PD. Conclusion: In view of the limited evidence of human studies and the sufficient evidence of experimental studies, the high exposure to anesthetic gases could have induced PD in the subject under study. © 2013 Mastrangelo et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Mastrangelo, G., Comiati, V., dell’Aquila, M., & Zamprogno, E. (2013). Exposure to anesthetic gases and Parkinson’s disease: A case report. BMC Neurology, 13. https://doi.org/10.1186/1471-2377-13-194

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free