Background: Sensitized fluorescence diagnostics are based on selective accumulation of photosensitizer in the tissue where carcinogenesis has started. The present study compared topical 5-aminolevulinic acid (5-ALA)-based fluorescence spectroscopy (FS) in vivo with conventional colposcopy for cervical intraepithelial neoplasia (CIN) detection. Methods: We enrolled 48 patients who were referred for colposcopy because of high-grade changes in cervical cytology. Every inspected cervix was divided in to quadrants, and there were 174 quadrants included in the study. Each patient had a cytological smear, colposcopy, FS and histopathological analysis. For FS, 3% 5-ALA cream was used topically and after an average 135min incubation, fluorescence spectra were recorded from the cervix in vivo. FS and colposcopy results were correlated with histopathology. Results: All spectra were evaluated by a ratio of the protoporphyrin IX fluorescence intensity at 634nm and autofluorescence intensity at 510nm. For proper grouping of low-risk and high-risk cases, a threshold of 3.87 was calculated. Data per quadrant showed that FS had higher sensitivity than colposcopy (71.7% vs 67.4%) but specificity was greater for colposcopy (86.6% vs 75.6%). Combination of the methods showed higher sensitivity (88.0% vs 67.4%) but reduced specificity (88.0% and 69.5%), but it had the highest number of correctly identified high-risk changes and the highest (79.3%) accuracy. Data for each patient showed FS sensitivity of 91.2%, which was greater than for colposcopy (88.2%). Higher overdiagnosis resulted in decreased specificity for fluorescence methodology-71.4% versus 78.6% for colposcopy. In both cases, accuracy was 85.4% and effectiveness was >80%, which means that both methods can be used to determine high-risk cervical intraepithelial neoplasia. The diagnostic sensitivity of 97.1% for this complementary diagnosis indicates that it could be the best choice for detection of high-risk changes. Conclusions: 5-ALA-based FS is an objective method, requiring short-term administration for appropriate fluorescence measurements. FS is a promising diagnostic tool with similar accuracy as colposcopy but with the potential advantage of providing objective results.
CITATION STYLE
Vansevičiute, R., Venius, J., Žukovskaja, O., Kanopiene, D., Letautiene, S., & Rotomskis, R. (2015). 5-Aminolevulinic-acid-based fluorescence spectroscopy and conventional colposcopy for in vivo detection of cervical pre-malignancy. BMC Women’s Health, 15(1). https://doi.org/10.1186/s12905-015-0191-4
Mendeley helps you to discover research relevant for your work.