High Speed, High Resolution and Low Cost Digital Radiography and Computed Tomography System

  • Rangarajan K
  • Jensen T
N/ACitations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Here, we will describe a new equivalent flaw s~z~ng method that provides an alternative solution to the zero-of-time problem and extends equivalent sizing methods to a wider range of flaw sizes. Specifically, we consider a time-of-flight equivalent (TOFE) sizing method that can size relatively large flaws by locating the zero-of-time with respect to the transducer and making simple time-of-flight measurements at a number of different transducer locations and orientations. We will demonstrate the performance of the TOFE sizing method on both synthetic and experimental data. TlME-OF-FLlGHT

Cite

CITATION STYLE

APA

Rangarajan, K., & Jensen, T. (1995). High Speed, High Resolution and Low Cost Digital Radiography and Computed Tomography System. In Review of Progress in Quantitative Nondestructive Evaluation (pp. 673–679). Springer US. https://doi.org/10.1007/978-1-4615-1987-4_83