ULTRASOUND SCAN

  • SABIH D
  • Ali F
  • ALIKHAN A
  • et al.
N/ACitations
Citations of this article
47Readers
Mendeley users who have this article in their library.

Abstract

O b j e c t i v e : To assess the infective potential of ultrasound gel and probes when used in a routine manner on ambulatorypatients with intact skin. At our institute, ultrasound probes are wiped with a non-sterile absorbent paper towel after each patient. The probesbecome dry and clean in social terms but we were unsure if they also became bacteriologically decontaminated after wiping clean. We alsowished to ascertain the intrinsic infective potential of ultrasound gel. Materials a n d m e t h o d s : Bacteriological samples were taken from probesurface (after wiping it clean as per our protocol); gel dispensing bottles; and the gel jars that contain the gel in bulk. A total of 61 sampleswere cultured, out of these 13 were jar samples that were acquired daily on 13 days, 10 from gel bottles and 38 from probe surface (27before beginning ultrasound, 11 after ending the day's work). Probe surface samples were collected on sterile cotton wipes dipped in sterilenutrient broth; bottle and jar samples were collected by sterile nickel loops and cultured on commercially available nutrient agar. Colonieswere counted at 24 and 48 hours. R e s u l t s : The results show bacterial contamination in all (10/10) gel bottle samples, 7% pre-scan probesurface wipes (2/27) and 27.3% (3/11) on post scan wipes. Gel Jar samples were sterile on the first 3 days and then progressively showedgreater colony counts. This showed that the gel is initially sterile but is apparently contaminated from air and it serves as growth mediumfor bacteria. C o n c l u s i o n : We conclude that the highest contamination is observed in gel bottle samples (100%). The lowest contaminationwas observed from wiped probe samples. This was probably due to repeated cleaning of probes by the operators. Gel jar samples havethe second highest contamination but the initial samples showed no growth. The ultrasound gels probably contain no or little antibacterialagent and the gel serves as a growth medium for bacteria.

Cite

CITATION STYLE

APA

SABIH, D.-E.-, Ali, F., ALIKHAN, A., Sajid, K. M., & JEHANGIR, W. (2009). ULTRASOUND SCAN. The Professional Medical Journal, 16(02), 293–297. https://doi.org/10.29309/tpmj/2009.16.02.2947

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free