Safety and efficacy of second-generation drug-eluting stents compared with bare-metal stents: An updated meta-analysis and regression of 9 randomized clinical trials

N/ACitations
Citations of this article
62Readers
Mendeley users who have this article in their library.

Abstract

The efficacy of second-generation drug-eluting stents (DES; eg, everolimus and zotarolimus) compared with bare-metal stents (BMS) in patients undergoing percutaneous coronary intervention was challenged recently by new evidence from large clinical trials. Thus, we aimed to conduct an updated systematic review and meta-analysis of randomized clinical trials (RCTs) evaluating the efficacy and safety of second-generation DES compared with BMS. Electronic databases were systematically searched for all RCTs comparing second-generation DES with BMS and reporting clinical outcomes. The primary efficacy outcome was major adverse cardiac events (MACE); the primary safety outcome was definite stent thrombosis. The DerSimonian and Laird method was used for estimation of summary risk ratios (RR). A total of 9 trials involving 17 682 patients were included in the final analysis. Compared with BMS, second-generation DES were associated with decreased incidence of MACE (RR: 0.78, 95% confidence interval [CI]: 0.69-0.88), driven by the decreased incidence of myocardial infarction (MI) (RR: 0.67, 95% CI: 0.48-0.95), target-lesion revascularization (RR: 0.47, 95% CI: 0.42-0.53), definite stent thrombosis (RR: 0.57, 95% CI: 0.41-0.78), and definite/probable stent thrombosis (RR: 0.54, 95% CI: 0.38-0.80). The incidence of all-cause mortality was similar between groups (RR: 0.94, 95% CI: 0.79-1.10). Meta-regression showed lower incidences of MI with DES implantation in elderly and diabetic patients (P = 0.026 and P < 0.0001, respectively). Compared with BMS, second-generation DES appear to be associated with a lower incidence of MACE, mainly driven by lower rates of target-lesion revascularization, MI, and stent thrombosis. However, all-cause mortality appears similar between groups.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mahmoud, A. N., Shah, N. H., Elgendy, I. Y., Agarwal, N., Elgendy, A. Y., Mentias, A., … Bavry, A. A. (2018, January 1). Safety and efficacy of second-generation drug-eluting stents compared with bare-metal stents: An updated meta-analysis and regression of 9 randomized clinical trials. Clinical Cardiology. John Wiley and Sons Inc. https://doi.org/10.1002/clc.22855

Readers over time

‘18‘19‘20‘21‘22‘23‘24‘2505101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 16

73%

Researcher 3

14%

Professor / Associate Prof. 2

9%

Lecturer / Post doc 1

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 9

53%

Nursing and Health Professions 4

24%

Pharmacology, Toxicology and Pharmaceut... 2

12%

Agricultural and Biological Sciences 2

12%

Save time finding and organizing research with Mendeley

Sign up for free
0