Baricity, needle direction, and intrathecal sufentanil labor analgesia

37Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

Abstract

Background: Intrathecal sufentanil relieves labor pain but centrally mediated side effects are common. Preventing rostral spread of intrathecal sufentanil should limit these side effects. Both direction of the lateral opening of a pencil-point needle and drug baricity modify the spread of intrathecal local anesthetics. This randomized, prospective, double-blind study examines the effects of these variables on intrathecal sufentanil labor analgesia. Methods: Forty laboring, full-term parturients, whose cervixes were dilated less than 5 cm and who requested analgesia for labor were enrolled. Combined spinal epidural analgesia was induced in patients in the sitting position. They were allocated to receive 10 μg intrathecal sufentanil diluted with either normal saline or dextrose with the aperture of the pencil point needle directed cephalad or caudad during drug injection. Thus there were four groups of ten patients: dextrose up, dextrose down, saline up, and saline down. Sufentanil was diluted with normal saline to a concentration of 10 μg/ml. The study drug was made by mixing 1 ml sufentanil solution with either 1 ml 10% dextrose or 1 ml normal saline. Visual analog scores for pain, pruritus, nausea, and pain relief were recorded before and 5, 10, 15, and 30 min after drug injection. Results: Baricity, but not needle orientation, influenced pain relief and pruritus. Sufentanil in dextrose produced less itching but also less analgesia. Nine of 20 women in the dextrose groups compared with 1 of 20 in the saline groups requested additional analgesia by 30 min. Conclusions: Little or no labor analgesia developed for patients receiving sufentanil with dextrose. A supraspinal action nay contribute to intrathecal sufentanil's analgesic efficacy.

References Powered by Scopus

Itching after epidural and spinal opiates

353Citations
N/AReaders
Get full text

Phase I safety assessment of intrathecal neostigmine methylsulfate in humans

255Citations
N/AReaders
Get full text

Hemodynamic and analgesic actions of epidurally administered clonidine

207Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Risk of respiratory arrest after intrathecal sufentanil

81Citations
N/AReaders
Get full text

The combined spinal-epidural technique

76Citations
N/AReaders
Get full text

Analgesia, pruritus, and ventilation exhibit a dose-response relationship in parturients receiving intrathecal fentanyl during labor

67Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ferouz, F., Norris, M. C., Arkoosh, V. A., Leighton, B. L., Boxer, L. M., & Corba, R. J. (1997). Baricity, needle direction, and intrathecal sufentanil labor analgesia. Anesthesiology, 86(3), 592–598. https://doi.org/10.1097/00000542-199703000-00010

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 13

65%

Researcher 3

15%

Professor / Associate Prof. 2

10%

Lecturer / Post doc 2

10%

Readers' Discipline

Tooltip

Medicine and Dentistry 15

63%

Nursing and Health Professions 4

17%

Psychology 3

13%

Agricultural and Biological Sciences 2

8%

Save time finding and organizing research with Mendeley

Sign up for free