Novel Extravascular Defibrillation Configuration With a Coil in the Substernal Space: The ASD Clinical Study

33Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives This study assessed the defibrillation efficacy of the substernal-lateral electrode configuration. Background Subcutaneous implantable cardioverter-defibrillators (ICDs) are regarded as alternatives to transvenous ICDs in certain subjects. However, substantially higher shock energy of up to 80 J may be required. Proposed is a new defibrillation method of placing the shock coil into the substernal space. Methods This prospective, nonrandomized, feasibility study was conducted in subjects scheduled for midline sternotomy or implant of ICD. A blunted end tunneling tool was used to insert a defibrillation lead behind the sternum using a percutaneous subxiphoid approach. A skin patch electrode was placed on the left mid-axillary line at the fourth to fifth intercostal space. After ventricular fibrillation induction, a single 35-J shock was delivered between the lead and skin patch. Results Sixteen subjects (12 males, 4 females; mean age: 61.6 ± 11.8 years) were enrolled. The mean lead placement time was 11.1 ± 6.6 min. Of the 14 subjects with successfully induced ventricular fibrillation episodes, 13 subjects (92.9%) had successful defibrillation. The 1 failure was associated with high and lateral shock coil placement. Mean ventricular fibrillation duration was 18.4 ± 5.6 s with a shock impedance of 98.1 ± 19.3 ohms. Of the 11 subjects with coil-patch electrograms, the average R-wave amplitude during sinus rhythm was 3.0 ± 1.4 mV. Conclusions These preliminary data demonstrate that substernal defibrillation is feasible and successful defibrillation can be achieved with the shock energy available in current transvenous ICDs. This may open new alternatives to extravascular ICD therapy.

Cite

CITATION STYLE

APA

Chan, J. Y. S., Lelakowski, J., Murgatroyd, F. D., Boersma, L. V., Cao, J., Nikolski, V., … Hall, M. C. S. (2017). Novel Extravascular Defibrillation Configuration With a Coil in the Substernal Space: The ASD Clinical Study. JACC: Clinical Electrophysiology, 3(8), 905–910. https://doi.org/10.1016/j.jacep.2016.12.026

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free