Purpose To evaluate the feasibility of SWIFT with variable flip angle (VFA) for measurement of T1 relaxation time in Gd-agarose-phantoms and osteochondral specimens, including regions of very short T2∗, and compare with T1 measured using standard methods Methods T1s of agarose phantoms with variable concentration of Gd-DTPA2- and nine pairs of native and trypsin-treated bovine cartilage-bone specimens were measured. For specimens, VFA-SWIFT, inversion recovery (IR) fast spin echo (FSE) and saturation recovery FSE were used. For phantoms, additionally spectroscopic IR was used. Differences and agreement between the methods were assessed using nonparametric Wilcoxon and Kruskal-Wallis tests and intraclass correlation. Results The different T1 mapping methods agreed well in the phantoms. VFA-SWIFT allowed reliable measurement of T1 in the osteochondral specimens, including regions where FSE-based methods failed. The T1s measured by VFA-SWIFT were shifted toward shorter values in specimens. However, the measurements correlated significantly (highest correlation VFA-SWIFT versus FSE was r = 0.966). SNR efficiency was generally highest for SWIFT, especially in the subchondral bone. Conclusion Feasibility of measuring T1 relaxation time using VFA-SWIFT in osteochondral specimens and phantoms was demonstrated. A shift toward shorter T1s was observed for VFA-SWIFT in specimens, reflecting the higher sensitivity of SWIFT to short T2∗ spins. Magn Reson Med 74:175-184, 2015.

References Powered by Scopus

Estimating kinetic parameters from dynamic contrast-enhanced T<inf>1</inf>- weighted MRI of a diffusable tracer: Standardized quantities and symbols

2817Citations
N/AReaders
Get full text

Time saving in measurement of NMR and EPR relaxation times

691Citations
N/AReaders
Get full text

Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging

596Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging

45Citations
N/AReaders
Get full text

Making the invisible visible - ultrashort echo time magnetic resonance imaging: Technical developments and applications

34Citations
N/AReaders
Get full text

Multifunctional Fe<inf>2</inf>O<inf>3</inf>@PPy-PEG nanocomposite for combination cancer therapy with MR imaging

28Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nissi, M. J., Lehto, L. J., Corum, C. A., Idiyatullin, D., Ellermann, J. M., Gröhn, O. H. J., & Nieminen, M. T. (2015). Measurement of T1 relaxation time of osteochondral specimens using VFA-SWIFT. Magnetic Resonance in Medicine, 74(1), 175–184. https://doi.org/10.1002/mrm.25398

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

58%

Researcher 5

42%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

43%

Engineering 4

29%

Physics and Astronomy 3

21%

Computer Science 1

7%

Save time finding and organizing research with Mendeley

Sign up for free