Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation

210Citations
Citations of this article
222Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To identify ventilatory setting adjustments that improve patient-ventilator synchrony during pressure-support ventilation in ventilator-dependent patients by reducing ineffective triggering events without decreasing tolerance. Design and setting: Prospective physiological study in a 13-bed medical intensive care unit in a university hospital. Patients and participants: Twelve intubated patients with more than 10% of ineffective breaths while receiving pressure-support ventilation. Interventions: Flow, airway-pressure, esophageal-pressure, and gastric-pressure signals were used to measure patient inspiratory effort. To decrease ineffective triggering the following ventilator setting adjustments were randomly adjusted: pressure support reduction, insufflation time reduction, and change in end-expiratory pressure. Measurements and results: Reducing pressure support from 20.0 cm H2O (IQR 19.5-20) to 13.0 (12.0-14.0) reduced tidal volume [10.2 ml/kg predicted body weight (7.2-11.5) to 5.9 (4.9-6.7)] and minimized ineffective triggering events [45% of respiratory efforts (36-52) to 0% (0-7)], completely abolishing ineffective triggering in two-thirds of patients. The ventilator respiratory rate increased due to unmasked wasted efforts, with no changes in patient respiratory rate [26.5 breaths/min (23.1-31.9) vs. 29.4 (24.6-34.5)], patient effort, or arterial PCO2. Shortening the insufflation time reduced ineffective triggering events and patient effort, while applying positive end-expiratory pressure had no influence on asynchrony. Conclusions: Markedly reducing pressure support or inspiratory duration to reach a tidal volume of about 6 ml/kg predicted body weight eliminated ineffective triggering in two-thirds of patients with weaning difficulties and a high percentage of ineffective efforts without inducing excessive work of breathing or modifying patient respiratory rate. © 2008 Springer-Verlag.

References Powered by Scopus

Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome

11143Citations
N/AReaders
Get full text

Characteristics and outcomes in adult patients receiving mechanical ventilation: A 28-day international study

1409Citations
N/AReaders
Get full text

Patient-ventilator asynchrony during assisted mechanical ventilation

690Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The application of esophageal pressure measurement in patients with respiratory failure

445Citations
N/AReaders
Get full text

Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives

377Citations
N/AReaders
Get full text

Asynchronies during mechanical ventilation are associated with mortality

371Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Thille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008). Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation. Intensive Care Medicine, 34(8), 1477–1486. https://doi.org/10.1007/s00134-008-1121-9

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 63

50%

Researcher 40

32%

Professor / Associate Prof. 18

14%

Lecturer / Post doc 5

4%

Readers' Discipline

Tooltip

Medicine and Dentistry 118

76%

Nursing and Health Professions 15

10%

Engineering 14

9%

Agricultural and Biological Sciences 8

5%

Article Metrics

Tooltip
Mentions
News Mentions: 2

Save time finding and organizing research with Mendeley

Sign up for free