Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design

30Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

Aims: This prospective, randomized study sought to directly compare the performance of paclitaxel and rapamycin on an otherwise identical, polymer-coated drug-eluting stent (DES) platform. Methods and results: Stents with identical design and biodegradable polymeric coating that elute either rapamycin or paclitaxel over a 2 months time period were utilized. In this pilot trial that included 91 patients, both stent platforms proved safe with no case of death, Q-wave myocardial infarction or stent thrombosis within a 9 months follow-up period. Late-lumen loss was markedly greater in the paclitaxel-eluting stent group compared with the rapamycin-eluting stent group (0.96 ± 0.75 vs. 0.33 ± 0.46 mm, P < 0.0001). Likewise, the rate of angiographic restenosis was higher in the paclitaxel-eluting stent group compared with the rapamycin-eluting stent group [39.0 vs. 12.2%; relative risk (RR) 3.20 (95% confidence interval, 1.29-7.92), P = 0.005]. Concomitantly, the need for target lesion revascularization was higher in the paclitaxel-eluting stent group compared with the rapamycin-eluting stent group [26.7 vs. 8.7%; RR 3.07 (1.07-8.80), P = 0.02]. Conclusion: The results of this clinical trial that is the first to directly compare the performance of paclitaxel and rapamycin on a DES platform otherwise identical in design and polymeric coating imply that rapamycin is more effective for the prevention of coronary restenosis on a DES platform with mid-term drug release and less dependent on release kinetics than paclitaxel. Thus, to ensure efficacy, drug release from a paclitaxel-coating stent platform must be prolonged and well controlled to achieve results that are comparable with the FDA-approved paclitaxel-eluting stent platform. © The Author 2007.

Cite

CITATION STYLE

APA

Wessely, R., Kastrati, A., Mehilli, J., Dibra, A., Pache, J., & Schömig, A. (2007). Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design. European Heart Journal, 28(22), 2720–2725. https://doi.org/10.1093/eurheartj/ehm425

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free